NYC 9/11 Public Portal Document
Attn: Benjamin Sallemi Received: 9/25/02 4:00:00 PM
ATC Associates Inc. ATC Group #: 8894
104 East 25th Street Analysis Date: 9/26/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-3280
Project: DEP Clean-up Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area :Von Asbestos a Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sp-5 SN (S/cc) (S/mm') (S/cc) Votes
11 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8894 -8
12 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8894 -9
13 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8894 -/0
14 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8,494 - / /
IS 1800.00 0.0450 0 None Detected 0 0 0.0048 < 22.24 <0.0048
•894 -/2
MARK PEYSAKHOV MICHAEL A. GORYCKI. Ph.D.
Analyzed by . . proved by'
~j
Disclaimer The laboratory is not responsible for data reported in structures/cc, which is dependent on volume coil by non laboratory personnel. This I my responsible
for data reported in structures/mm2 This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government. This reports relates only to the samples reported above. Quality control data (including 95%
• confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLMITEM #101187.0, NY State ELAP #10879
Page 2 of'
NYC-WTC 000129897
OCR can misread numbers and units. Confirm readings against the page image before using them.