NYC-WTC_000127626
Document page displaying raw analytical data or charts related to asbestos testing for 92 Fulton Street.
15 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Letter dated October 4, 2002 from Management Corp enclosing executed asbestos permit applications for 100 Church Street.
NYC-WTC_000126787–000126817Folder label: “100 CHURCH ST 1001409, 125/20”

OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document NYCDEP B+11 RSB/ hltw i rcu SEfl-13-2 2 15:39
fi1Qdiag Facade Clean' 1P .ti NYCDEP and NYSDOL asbestos contractor with Work shall be performed by a NYSDOL licensed asbestos certified workers. facades. should be experienced in cleaning building The caatraetor Performing the cleaning cleuan~ng shall ("specified area") by DEP. The area below the as ACM The clean up area shall be specified All debris must be collected be covered with a layer of pvlyethy es sheeting. ust bedouble bagged waste lsbe; eMd the surface. (i.e. directly upon, removal from is not water runoff on the building façade bags.) Runnug water or :ball 0d prior to e cleaning. Access to the street below the façade wind Building OMV with caution tape. Cleaning shall not be pe=rforms] during cleaning shall be restricted and marked speeds greater than 20 mph. =hall be Closed during the conditioners shall be turned off All windows scaling with duct tape to All HVAC systems and air conditioners and windows may requite cleaning of the building. Some or prevent water penetration. the roof; All clesn-up activities on the roof muse be where __..;'anent is rijzed from root: completed prior to rigging equipment from the ma st by wetting the facade sisal] be cleaned of large bulk All horizontal surfacer and all windows on non-metallic creepers, by wet wiping ~-metallic bristle brasher or wiping and low- and hand brushing or scraping with bottom. Only water shall be used for wet from top to hibited. or by HEPA vactnuniag solvents, additives, and any other chemical clesaaing agents wet pressure washing. Detergents, placed into containers (e.g. bags). Windows shall be The removed material shall be immediately during this procedure.Power for HEPA vacuums shall be wiped. Free running water shall not be evident supplied through ground fault interrupters. carefully washed. A low pressure washing of debris removal, the specified area shalltobem Facades abet] After completion t to employed inimize water bauace-byck. technique, moving from top to bottom, shall be 250 psi. exceed be washed with a low-pressure wash not to to of the abated surfaces and sidewalk shall be performed At the completion of work, a visual won verify the absence of visible debris. an inde peaftt NYSDOL licensed third party air Monitor i rm Air monitoring shall be performed by with certified workers. recomniendead this work minimize disruption to the public and to the building occupants, it is In order to be peribrrned during off-hours.
Page 5 05/03/02
NYC-WTC 000126813
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000127626
Document page displaying raw analytical data or charts related to asbestos testing for 92 Fulton Street.
15 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗16 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000117975
Agreement between NYC DEP and a landowner to remove foreign material from building exteriors near the WTC site.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000128450
Formal agreement between the City and a landowner regarding the removal of foreign material from building exteriors at 94 Greenwich Street.
15 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000110854
Letter submitting executed license agreements for asbestos cleaning at a Lower Manhattan building to DEP.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000116365
License agreement between NYC DEP and a landowner regarding debris removal from exterior areas of 300 Albany Street.
14 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118972
Facility inspection form documenting ACM and air monitoring status for a building at 65 Beaver Street.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000119306
Letter submitting a signed license agreement for the cleaning of the exterior of 17 Battery Place to DEP.
17 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000113055
Legal agreement between the City of New York and a landowner to remove foreign material from building exteriors.
17 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118585
Final notice letter regarding WTC debris on exterior surfaces of 45 Broad Street dated September 3, 2002.
17 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118359
Agreement between the City of New York and 60 Broad Street LLC for removing foreign material from building exteriors.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000118384
Agreement between the City of New York and 60 Broad Street LLC for removing foreign material from building exteriors.
16 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
Page similarity is temporarily unavailable or this page has no indexed vector.
Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Filed in the same folder
NYC-WTC_000126784
Form recording visual inspection results of building facades and air monitoring status for a structure affected by WTC debris.
Filed in the same folder
NYC-WTC_000126818
Laboratory report from Athena dated October 27, 2002 detailing transmission electron microscopy results for airborne asbestos samples.
Filed in the same folder
NYC-WTC_000126820
Laboratory report detailing airborne asbestos analysis results for 100 Church Street conducted in October 2002.
Filed in the same folder
NYC-WTC_000126822
Laboratory report detailing airborne asbestos analysis results for 100 Church Street conducted in October 2002.
Filed in the same folder