Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

NYC-WTC_000121516–000121803

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600

Page image
Scanned page image, NYC-WTC_000121518
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

1.0 Introduction January 2, 2002

Gateway Plaza Management Corporation 375 South End Avenue New York, New York 10280

Subject: Gateway Plaza Balding #600

Gentlemen:

ALC Environmental Incorporated (ALC) has beCh Contracted by to perform visual assessments, bulk sampling, and air sampling to identify any asbestos contaminant at the above referenced building. ALC performed sampling according to the EPA Guidelines for asbestos bulk sampling and air sampling. The inspections were conducted in this building on September 20, October 3, 22, 23,23, & November 20, December 11, 12,13,14, 15, 16, &17 2001.

ALC worked under the guidance provided by the EPA guidelines for asbestos-"Asbestos in Buildings: Simplify Sampling Schemefor Friable Surfacing Materials." and the direction of the Department of Environmental Protection (DEP) to perform the bulk sample collection and analysis. Additionally, ALC provided on site Third Party Air Monitoring and Project Management, which included performing area air sampling each floor of the building, supervising the clean-up activities in specific apartments where on

minimal asbestos was found-even though further analysis at a second laboratory showed the results to be below the permissible limits-, performing quality assurance inspections and monitoring the work practices of the Asbestos Abatement Contractor. Air Sampling was conducted in accordance with Federal State and Local regulations including New York City Department of Environmental Protection (NYC-DEP) Title 15, Chapter 1, Asbestos Control Program Subchapter D, "Air and Bulk Sampling, Monitoring and Analysis: and New York State Department of Labor Industrial Code Rule 56 (NYS-DOL ICR56) Section 56-17 "Air Sampling, Monitoring and Analysis."

ALC is licensed to perform asbestos activities by the State of New York Department of Labor (License # 00-0358). ALC employs only certified asbestos personnel to perform required tasks. The following personnel were used to perform asbestos air monitoring and/or asbestos inspections.

Project Manager Inspector/Project Monitor. America Rodriguez Jr. (License #AH 89-07160) Inspector: Alvin R. Blake (License #AH 00-08397) Project Monitor: Yakhov Benyaguya (License #AH 95-21191) Sampling Technician: Alvin B. Blake (License #AH 01-03528) Shane Schoffner (License #AH 315404) ATC Associates 104 East 25th Street New York, New York analyzed all samples. Further analysis was performed by SciLab 117 East 30th Street New York, New York.

If you have any questions or comments please do not hesitate to contact us directly at 212-279-1001.

Sincerely,

Joshua Sarett ALC Environmental Incorporated

NYC-WTC 000121518

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121518Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121804 · Box DEP Box 48

Memo from a DEP contractor reporting on visual inspections of ventilation systems for WTC dust contamination at 395 South End Avenue.

Filed in the same folder

Compare copies and versions →