NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600
Document / 288 pages

Chain of custody for bulk sampling at 395 South End

Machine-extracted title · confidence 95%

Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

NYC-WTC_000121516–000121803

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600

Page image
Scanned page image, NYC-WTC_000121786
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Received: 12/19/01 5.00:00 AM Attn: Mr. Joshua Sarett ALC Environmental ATC Group #: 6143 115 W. 30th Street NY 10001 Analysis Date: 12/19/01 New York

Fax: (212) 279-6747 Phone: (212) 27.9-1001

Project: Gateway Plaza Management York NY 395 Southerd Ave. , Blds 600. New

Electron Microscopy (TEM) Performed Asbestos Fiber Analysis by Transmission by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Asbestos Structures Sensitivity Concentration Area Nor' Ash Typefs) 0.5p.5 5p (S/cc) (S/mm) (S/cc) Notes Sample Volume Anal,^~d 0 0 0.0048 <22.24 <0.0048 19 1800.00 00450 0 None OeteCad 6143 -19

N0ee0e!acted 0 0 0.0048 <2224 <0.0045 20 1800.00 00450 0 6143 •20

0 0 0.0048 <22.24 <0 U048 22 1 180000 0.0450 0 None 0eteccleo 6143 -21

0 0 0.0048 <22.24 <0.0048 21 1800.1)0 O.v450 0 yonsDetected 6t43 _72

0 0.0048 <22.24 <0.0048 23 1800.00 0.0450 0 None 0e1ec1ed 0 6143 -23

0 0 0.0048 <22.24 <00048 =4 1900.00 00450 0 Nam Detect 6143 -24

9

,MICHAEL A. GORYCKI, Ph.D. ROMAN PEYSAKHOV _ APPcoved by: Analysed by:

resDonsinle collected by no-laboratory Perso'mU. This lab is only rePoRed in sUudwm/ec tvflrctt is dependent On vo,me • OittCiLfnCt: The Wbonnry a not responsible for eta reproduced. accept i+ ful. wima 4 writtse approves try Alt 1Lssociates Inc. Tnls report may not be used to rune for aata reported to see to rattmm'. This report may not be reported above. Quaf ly control data (nctud ng 95t4 of the U.S. Government. This reports relates only to the samples pareses enooaement oy NVLAP at any other agency IS avail upon request cnntdanoa broils and laboretory and anatysW accuracy and precision) 910879 Accredited tot NVIAP PtWTEM v101187-0, NY State FLAP

NYC-WTC 000121786

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121786Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121804 · Box DEP Box 48

Memo from a DEP contractor reporting on visual inspections of ventilation systems for WTC dust contamination at 395 South End Avenue.

Filed in the same folder

Compare copies and versions →