NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600
Document / 288 pages

Chain of custody for bulk sampling at 395 South End

Machine-extracted title · confidence 95%

Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

NYC-WTC_000121516–000121803

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600

Page image
Scanned page image, NYC-WTC_000121768
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

ATC Associates N`Y 10010 104 East 25 Street, New York, Phone: (2l2)353.280 Fax: (212) 353-8306

Received: 12!18/01 8.00.00 AM Attn: Mr Joshua Satedl ALC Environmental ATC Group #: 6132 115 W 30th Street Aoatysis Date: 12/18/01 NY 10001 New York Phone: (212)279- 1001 Fax: (212)279-674"

Project: Gateway Plaza Managetnent 600. New York, NY 395 Southerd Ave , Bldg. EM) Performed Analysis by Transmission Electron Microscopes Asbestos Fiber ) by EPA 40 CFR Part 763 Final Rule (AHE Analytical Asbestos Acbestu( Structure Sensitivity Conceutratton Area (S/cc) (S/mm') (S/cc) Note Asbsb es) Types) &3-5 Sv Lamp's Volume Analyzed 0.0048 <22.24 <0.0048 None Detected 0 0 D-1 1800.00 0.0450 0 6132 - 1 —. •-- — - -- .-- -- <00048 0 0 0.0048 <2224 0.0450 0 NOre 0etamed 0-2 1600.00 6132.2 — -• — — 0 0 0.0048 <22.24 <0.0048 D.1 , 800.00 0.0450 0 Note Detected _ 6132-3 <22.24 <0.0048 0 0 0 0048 00450 0 None Detected D-4 1800.00 — — 6132-4 —' 0 0 00048 < 22 24 <0.0048 D-5 1800.00 0.0450 0 None Oetectea 6132 -5 0.0048 <22.24 <00048 Nona DeteCGa 0 0 D•6 180000 0.0450 0 6132 -6

MICHAEL A GORYCKI, Ph.D .

MARK PEYSAKHOy Approved by: Analyzed by~~ --- _ non-Iebdtatory 0er3Cnnet. This loo a on;y resConsIble slruaurvs/o~. which is dependent on volume collected by tno The report mey not be used ;o Gam Otsda rr'. The tabors". b not rosy is to a for aata ra p In cept In tug. without wtitttn approval by ATC Associates This rappel may not be reprCdtrced ex relates only to the samples reported above. p,aary cdrucl data (uwludinc 95'. tar data respond et stntctutrslmm' other agency at Me U.S GOle nmeta This tepdtts product ertcoaement by NVLAP or any 050181 15 avadaote upon requesL con6derce units and laboratory and ana-ysis' accwacy and

2101187-0. NY State ELAP *10879 Ac:eddeo for NVLAP PLWTE!u

NYC-WTC 000121768

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121768Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121804 · Box DEP Box 48

Memo from a DEP contractor reporting on visual inspections of ventilation systems for WTC dust contamination at 395 South End Avenue.

Filed in the same folder

Compare copies and versions →