NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600
Document / 288 pages

Chain of custody for bulk sampling at 395 South End

Machine-extracted title · confidence 95%

Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

NYC-WTC_000121516–000121803

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600

Page image
Scanned page image, NYC-WTC_000121694
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document `'t ATC Associates 104 East 25 Street; New York, NY 10010 Phone: (212) 353-8280 Fax: (212) 353-8306

Attn: Mr. Joshua Sarett ALC Environmental Received: 12/17/01 700.00 AM 115 W. 30th Street ATC Group *: 6123 New York NY 10001 Analysis Date: 12/17/0) Fax: (212) 279-6747 Phone: (212) 279-1001 Project: Gateway Plaza Management 395 Southerd Ave. , ,81dg. 600. New York , NY

Asbestos Fiber Analysis by Transmission EIectron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Arraiyrital Asbanos Ar ra Nan .Isbtetor Snucnsres Sensiriviry Coacentrauon Sample velum. Anatyrcd Ash 7)'pe(s1 Q5p4 5p (Y/cc) D-1 (54nvrr0 (S/cc) Notes 1800.00 0.0450 0 None detected 0 0 0.0048 <22.24 <0.0448 15123-1

1800.00 0.0450 0 Nona Dejected 0 6123 -2 0 0.0048 <22.24 <0 0048

D-3 1500.00 0.0450 0 NoneDeraezed 0 b 123 -3 0 0.0048 <22.24 <00048

0-4 180000 0.0450 0 CHRYSOTILE I 0 0.0048 22.24 0.0048 0123 -4 _ --

D-5 1800.00 0.0450 0 None Delectod 0 0 0.0048 6123 -5 <22.24 <0,0048 D-6.... 1800.00 0.0450 0 None Detected 0 0 6123 -6 00048 <22.24 <0.0048

D9 1800.00 0.0450 0 None Detected 0 0 6123 -7 ... 0.0048 <22.24 <0.0048 .. _ ..~ -- D-8 1800.00 0.0450 0 blunt 0e ted -- - _. 6123 -8 0 0 0.0048 <22.24 <0.0048

ROMAN PEYSAKHOV MICHAEL A. GORYCKI, Ph.D. Analyzed by: u~/ J,(Q- - - Approved by-. -

Dudaimer The l botatory is not rasponnele for data reported n strtcin$ftc. efllrh for data reported in suudtneshnmr. This rport may not be reprodtreed, except in 611, is dependent on volume coeected by non-laboratory pernonnd. This lab is only responsible +riMout product endorsement by NVLAP or any otter agency of ttaU.S Government. This tapmrts wthen approval by ATC Assoc tales Inc. This report may not be used to claim relates only to the samples reported above. Quality control data (includ►np 93% con(genoe limits and labors" and analysis' accuracy and pieds orb) is av&abla upon request. Accredited for NVL4P PLMlIEM 0101187-0. NY State EtAP #10879

NYC-WTC 000121694

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121694Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121804 · Box DEP Box 48

Memo from a DEP contractor reporting on visual inspections of ventilation systems for WTC dust contamination at 395 South End Avenue.

Filed in the same folder

Compare copies and versions →