NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 48/345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600
Document / 288 pages

Chain of custody for bulk sampling at 395 South End

Machine-extracted title · confidence 95%

Document tracking environmental samples collected from Building #600 at 395 South End Avenue on January 2, 2002.

NYC-WTC_000121516–000121803

Folder label: “345 SOUTH END AVENUE Block: 16 Lot: 100 BIN: 1083375 395 South End Ave, Building #600

Page image
Scanned page image, NYC-WTC_000121676
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document Ann. Mr. Joshua Saren ALC Environmental Received: I2118/01 800.00 AM 115 W. 30th Street ATC Group #: 6137 New York NY 10001 Analysis Date: 12/I8/01 Fax- (2]2) 279-6747 Phone: (212) 279-1001 Project. Gateway Plaza Management 395 Southard Avc. , Bldg. 600, New York , NY

Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed by EPA 40 CFR Part 763 Final Rule (AHERA) Analytical Asbestos Area Na, Asbestos Structures Seasitfvity Concentration Sample Volume Analyzed Asb Type(s) 05p5 S (S/cc) (S/tten.') (s/cel Notes D-9 1800.00 0.0450 0 None Detected 0 6137-9 0 00048 <22.24 <0.0048

0-10 180000 0.0450 0 None 0etected 0 0 0.0048 <22.24 6137 -10 <0.0048

D• 1 i 1800.00 0.0450 U None Detected • 6137 -11

0.12 0 0 0.0048 < 22.24 -4 0.0048

1800 00 0.0450 0 None Detecteo 0 0 0.0048 6137 -12 <22.24 <0.0048

0-13 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048 0137 -13

1500.00 0.0450 0 None Detected 0 0 0.0048 <22.24 6137 -]4 <0.0048 -~

015 180000 0.0450 0 Nona Oeteaed 0 0 0.0048 -2224 <0.0048 6137 -15

D-t6 1800.00 0.0450 0 CHRYSOTILE 0 1 0.0048 22.24 6137 -16 0.0048

U-17 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048 6137.17

40 D-18 6137 -18 1800.00 0.0450 0 None Deaclad 0 0 0.0048 <22.24 <0.0048

MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D Analyrcd by: .- Approved by:

OisWirner. The laboratory is not responsible for data reported in strucnuaslce, which s depondent on volume collected by non-Vboratory personnel. for doer reported in stnteatreslmrrf. This report may not be repm*xtd, except In full. without wrifen approval by The lab is onty responsible ATC Associates Inc. The report may net be used to clalm pin endocwlent by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95% confidence Emits and aboratory and analysis accuracy and prec onl is avaaable upon request

Accredited for NVLAP PLM!TEM #1101187-0. NY State ELAP #10879

NYC-WTC 000121676

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000121676Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000121804 · Box DEP Box 48

Memo from a DEP contractor reporting on visual inspections of ventilation systems for WTC dust contamination at 395 South End Avenue.

Filed in the same folder

Compare copies and versions →