09/17/2001 12:09 2123533599 ATC ASSOCIATES INC PAGE 07/12
ATC ASSOCIATES, INC
104 E 25th Street, 10th Floor
New York, NY 10010
TeL 212-353-8280
Fax 212-353-8306
REPORT DATE: 09-17-01
CLIENT: Scientific Laboratories, IncJUR$ Corp
PROJECT LOCATON: Peck Stip Statior., NYC - 2 Flo r
SAMPLED BY: Client
SAMPLE DATE: 09-16-01
DATE RECEIVED: 09-17-01
DATE ANALYZED: 09-17-01
SAMPLE MEDIA: Air Samples
ANALYSIS REQUIRED: Method NIOS1{ 1082
ANALYSIS RESULTS
SAMPLE BATCH S.4M?LL• DESCRIPTION LEAD DETECTION
1D NO. CONCENTRATION LIMIT
(µI.:2)
2P1L1 14027 Air Sample <1.4 1.4
2?2L2 14027 Air Sample 7S 1.2
2P3L3 14027 Air Sample <1.3 1.3
2P4L4 14021 Air Sample <1.3 1.3
2PSL5 14027 Air Sample <1.3 1.3
NOTE!
THE REPORTING LIMIT (RL) IS 3.0 µg
NOTE 2:
At the prce rtt time there are no regclatory levek or requirements 1ar indcor a rto e lead in area samptcc. Howevct, OSFIA Ls
csteblished at action level of 30 µg/tn' and a permisibte exposure level (PEL) cf SO µg/it ' for persona( samples.
CERTIFICATION AND SIGNATURES
ANALYSIS PERFORMED BY: J,I C
REPORT PREPARED BY:
ATC certifies that this report is an accurate and authentic report of resins obtained from the laborc:or) analysis.
QUALITY ASSURANCE COORDINATOR: U''
LABORATORY DIRECTOR:
ATC Environmental Inc. (ATC) is accredited by the New York. Sa:c Depar_;frnt of Health Env!roar.:cnta! Labor_:cry Approval
1'rogr3rn (NYS DOH ELAP) to perform analysis of lend in paint Ind doss wipes (1 LAP b 10379).
SEP 17 2001 12:25 2123533599 PAGE.O?
NYC-WTC 000120335