NYC 9/11 Public Portal Document
AIRTEK Date: 12/12/01 Proj Num: 01-1213
ENVIRONMENTAL Page: 106
AIR SAMPLING RESULTS
CORP Code: IL
--Types of Project-- Address:EM&CA
53 PARK PLACE
6TH FLOOR
State: Zip:
Date Analyzed: 12/13/01
Sample IL -1212-156 IL -1212-157 IL -1212-158 IL -1212-159 IL -1212-160
cation WA,6TH FL. OWA,6TH FL. OWA,6TH FL. OWA,6TH FL. OWA,6TH FL.
1 OUTSIDE W/A
Y THE
OUTSIDE W/A
3Y THE
OUTSIDE W/A
BY THE
OUTSIDE W/A
3Y THE ROOM
OUTSIDE W/A
BY THE ROOM
LEVATOR STAIRCASE A LAUNDRY 6C 6G
ctivity OST ABATEMENT POST ABATEMENT POST ABATEMENT POST ABATEMENT POST ABATEMENT
Personal
vg Flow 15.0 15.0 15.0 15.0 15.0
al Date 2/12/01 12/12/01 12/12/01 12/12/01 12/12/01
ime On 9:20A 09:21A 09:22A 09:23A 09:24A
ime Off 1:20A 11:21A 11:22A 11:23A 11:24A
of Time 20 min 120 min 120 min 120 min 120 min
of Vol 800 ltr 1800 ltr 1800 ltr 1800 ltr 1800 ltr
V Cnt
Fibr
Per Fld .015 .09 .125 .035 .19
ribr Cnt
Fibr
Per CC 0.0015 0.0025 0.0034 0.0015 0.0052
Comments
ANALYSIS: NIOSH 7400 METHOD, A RULES - NIKON LABC - PCM ___..... .. ....