Agency.
EPA or USEPA: United States Environmental Protection
type of ACM and/or where one
Homogeneous Work Area: Portion of the Work Area that contains one
type of abatement is used.
measurement protocol for the assessment for the fiber
Phase Contrast Microscopy: "PCM" shall mean the
considered satisfactory when every
content of air. For PCM analysis, the clearance air monitoring shall be
concentrations, whichever is greater.
sample is less than or equal to 0.01 f/cc or the background
for the assessment for the
Polarized Light Microscopy: "PLM"shall mean the measurement protocol
For PLM analysis, the New York City and EPA Regulatory limit is
asbestos content of bulk materials.
1 .0%.
assessment for
Transmission Electron Microscopy: "TEM"shall mean the measurement protocol for the
air monitoring shall be considered
the asbestos fiber content of air. For TEM analysis. the clearance
satisfactory when the requirements stated in 40 CFR Part 763, Subpart E. Appendix A, Section IV are met.
For the purposes of our testing the regulatory limit is 70 asbestos structures per mm2.
• 4.0 Scope of Work
4.1 Bulk Sampling Procedures
guidelines for
ALC's licensed technicians worked under the guidance provided by the EPA
Buildings: Simplify Sampling Scheme for Friable Surfacing Materials."
asbestos-"Asbestos in
procedure uses random sampling to ensure that the samples are representative of the
This sampling
sampling area. ALC's inspectors:
Identified all friable surfacing materials and grouped them into homogenous sampling
areas by floor
2. Prepared diagrams of each sampling area
3. Determine the number of samples to collect (9 samples per homogenous areas are
recommended) Determine sampling locations
4. Collect samples
• 5. Fill out chain of custody
6. Send samples to a qualified laboratory
public areas of the
Due to the insufficient amount of dust and debris in the apartment units and
building, we were unable to collect the optimum number of samples suggested in the above
referenced guidelines.
went to each floor and
With the guidance of the above referenced document and NYCDEP we
and debris. Upon completion of the initial
assessed each apartment on each floor for visible dust
assessment and bulk sample collection, ALC determined that there were no elevated asbestos
in any of the apartments where samples were taken.
levels present above the guidelines
collected a bulk sample and sent it to the
If any dust and/or debris was found in the apartment we
laboratory for analysis.
we were in the
If no sample could be taken due to insufficient material present at the time
apartment, the inspector documented this on the log.
NYC-WTC 000119867