NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 46/2 SOUTH END av 1082813, 16/7511
Document / 62 pages

HVAC inspection report, 2 South End Ave, Jan 2003

Machine-extracted title · confidence 92%

Duplicate or continuation of the Athenica Environmental Services letter regarding HVAC inspections at 2 South End Avenue.

NYC-WTC_000117893–000117954

Folder label: “2 SOUTH END av 1082813, 16/7511

Page image
Scanned page image, NYC-WTC_000117929
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 2.2 __ Mechanical Exhaust System Visual Inspection Form Mechanical Exhaust System: Identification: age 1 of 1 MECHANICAL Extausy Fancth 33 Location Area Served: Lowe® Roor - 2 soute eu AvE Associated mechanical roor:: clean /Y___N dry / Y N stored chemicals/refuse__- -Y_~» N- System Components [NOTE: if component not present (NP), net found (NF) or inaccessible @® please indicate in last column) . ' Surface Dust/ Debris Present? Component © not present * not found © inaccessible Exhaust air outlet: Location: Accessible for inspection? *{_4/ N (explain); —_louvers, grates and/or s:reens —_ outside air duct —_Outside air damper(s) Exhaust fan unit: — blower assembly incl, tiower wheel, housing, air Vanes, in-line noise attenuators ~_blower housing acoustical lining PL ML Th RS — Vibration collars NP Exhaust air distribution: — Exhaust air ducte Est. cotal In ft 2D Specify type (circle): (etal) fitraus glans lined metal fiex-duct wood No. locations inspected _O4 masonry fibrous glass board — Accessible in-line fire dampers Est, total qty __2\ No. locations inspected © ~ Accessible turning vanes Est. total qty No. locations inspected ~ Exhaust air grilles Est. total qty A No. locations inspected O Other (specify): Other Information: AND fis AssoamiED Deets, KEY: NP = not present; N¥ = not found; I = inaccessible; U = unknown NYC-WTC_000117929 General impression Gadica:e recommendations for cleaning based ox finding of WIC dust): m= NO WIE RaeaTen Dost was oBszeven 10 THE Hecuanicne CoHPOREATS _ No CLEAN ING 13 ®EQvu IPED FoR uWsTe EECATED Bv57,

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117929Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117830 · Box DEP Box 46

Detailed list of mechanical components including fans, ducts, dampers, and grilles located at the South End Avenue facility.

Filed in the same folder

NYC-WTC_000117831 · Box DEP Box 46

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed on January 15, 2003.

Filed in the same folder

Compare copies and versions →