HVAC inspection report, 2 South End Ave, Jan 2003

Machine-extracted title · confidence 92%

Letter from Athenica Environmental Services reporting HVAC and environmental inspections performed on January 15, 2003.

NYC-WTC_000117831–000117892

Folder label: “2 SOUTH END av 1082813, 16/7511

Page image
Scanned page image, NYC-WTC_000117877
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document 22 Mechanical Exhaust System Visual Inspection Form Mschativai Exnaust Syster: Identification: Location: MECHANKAL EXHAUST FAN# 43 LOWER RODF - 2 SOUTHENDArE Area Served: Associated mechanical roorr: clean_LY_ _N dry <X N System Components (NOTE: if component not present (NP), not frand (NF') or inaccessible (I) please indicate in last column] Exhaust air outlet: Location: Page 1 of 1 stored chemicals/refuse_ YxN Surface Dast/ Debris Present? Accessible for inspection? 1 N _(explain): - louvers, grates and/or s:reens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. tlower wheel, housing, air vanes, in-line noise attenuators - blower housing acousti.al lining - Vibration collars Exhaust air distribution: - Exhaust air ducts Est otai inft 20 Specify type (circie): aeta) No. locations iaspected o1 ) fibrous plass lined metal. masonry fibrous glass board Dex-duct wood - Accessible in-line fire danipers Est. total qty - Accessible tuming vanes Est. total qty - Exhaust air grilles Other (specify): Est. total qty. g - No. locations inspected_O No. locations inspected No. locations inspected_O Other Information: THe FAN iS Not WoRKING Component WTC • not present Dust Present? not fouad • inaccessible Y N N N N N NP Y N I NP. General impression (indica :e recommendations for cleaning based oa finding of WTC dust): - NO LOTE RELATED DUST WAS OBSERUED IN THE MECHANICAL COMPONENTS AND MS ASSOGIATED DUCTS. - NO CLEANING IS REQUIRED FOR WTC RELATED BUST. KEY: NP = not present; NF = not fouud; I = inaccessible; U = unknown NYC-WTC_000117877

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000117877Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000117830 · Box DEP Box 46

Detailed list of mechanical components including fans, ducts, dampers, and grilles located at the South End Avenue facility.

Filed in the same folder

NYC-WTC_000117893 · Box DEP Box 46

Duplicate or continuation of the Athenica Environmental Services letter regarding HVAC inspections at 2 South End Avenue.

Filed in the same folder

Compare copies and versions →