NYC 9/11 Public Portal Document ical Exhausi Exnaust System Visual Inspection Form Mechanical Exhaust System Identification: Location: MECHANICAL EXHAUST FAN#4 16"t200R-ROCF -350 ALBANY SRETT Associated mechanical room: clean _Y_ _N dry System Components indicate in last column] (NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Exhaust air outlet: Location: Page 1 of 1 Area Served: nal • APTs. 2iif 70 stored chemicals/refuse Surface Dust/ Debris Present? 15FL00R €$ PENTHOUSE #2 Accessible for inspection? Y N _(explain): - louvers. grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - vibration collars Exhaust air distribution: - Exhaust air ducts Est. total In ft Specify type (circle): 160 metal No. locations inspected fbrous glass lined meta masonry fibrous glass board Llex-duct wood - Accessible in-line fire dampers Est. total qty 15 - Accessible turing vanes Est. total gty - Exhaust air grilles Other (specify): Est. total gty. No. locations inspected_0 No. locations inspected 15 - No. locations inspected_6 Other Information: THE UNIT IS NOT WORKING. WIC Dust Present? Component • not present • not found •inaccessible Y Y NP Y NP Y I NP I GeeEeDuStdd NE CLDOUZiTS OF THE FAN ABOVE AND BELOW THE LOUVERS. WTC PHATED DUST WAS OBSEEVED IN THE DUCTWORK CLEANING FOR LOTC RELATED DUST IS RECOMHENDED CLEAN THE COMPONENTS OF THE FAN AND ITS ASSOCIATED DUCTLRORK. KEY: NP = not present; NF = not found; I = inaccessible; U = unknown NYC-WTC_000116242

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116242Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →