Building inspection checklist for 300 Albany Street

Machine-extracted title · confidence 90%

Form documenting building details and inspection results for 300 Albany Street, including checks for ACM, air monitoring, and facade conditions.

NYC-WTC_000116234–000116267

Folder label: “320 ALBANY STREET 000301, 16/7502”

Page image
Scanned page image, NYC-WTC_000116250
OCR text

OCR status: ocr · source: ours

NYC 9/11 Public Portal Document bod wecuanical Exnaust System Visual Inspection Form Mechanical Exhaust System Identification: MECHANICAL EXHAUSY FAN #5 Location: MFLOER- ROCF 350 ALZANY STREET Area Served: KITCHENS # BATHROOMS Associated mechanical room: clean_ Y_N dryY_ _N stored chemicals/refuse Y System Components Surface [NOTE: if component not present (NP), not found (NF) or inaccessible (I) please Dust/ indicate in last column] Debris Present? Exhaust air outlet: Location: Accessible for inspection? Y_ _(explain): - louvers. grates and/or screens - outside air duct - outside air damper(s) Exhaust fan unit: - blower assembly incl. blower wheel, housing, air vanes, in-line noise attenuators - blower housing acoustical lining - Vibration collars Exhaust air distribution: - Exhaust air ducts Est. total In ft 60 No. locations inspected_ 1 'Specify type (circle): meta fibrous glass lined metal masonry fbrous glass board flex-duct wood - Accessible in-line fire dampers Est. total gty_ 5 - Accessible turning vanes Est. total qty. - Exhaust air grilles Est. total qty 5 No. locations inspected O No. locations inspected No. locations inspected 0 Other (specify): Y Y Y Other Information: Page 1 of1 _N WTC Dust Present? Component • not present • not found • inaccessible NP NP NP General impression (indicate recommendations for cleaning based on finding of WTC dust): - WTC DEBRIS WAS OBSERVED IN THE COMPNENTS OF THE FAN, ASCUE ASD PEUSIA THE LOUVERS, SOME ATTEMPT TO GLEANT: LDAS MADE, BHTNNTG STILL un WTC DEBKIS WAS EBSERUED IN THE DUCTWORK. _ CLEANING FOR WTE DEBRIS IS RECOHHENDED. n CIEAN THE EXHAUST FAN UNIT AND ATS ASSICIATED DUCTUORK. KEY: NP = not present; NF = not found; I = inaccessible; U = unknown NYC-WTC_000116250

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000116250Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →