NYC 9/11 Public Portal Document
EMSL Analytical, Inc. Carle Place, NY 11514
Phone: (516) 997-7251 Fax: (516) 997-7528
Attn.:
Commercial Lab Enterprise Tuesday, October 23, 2001
270 Swinton Avenue
Bronx, NY 10465 Ref Number: L10116152
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM)
Performed by EPA 40 CFR Part 763 Final Rule (AHERA)
Project: BUILDING #9310 GRENNWICH STREET NYC, NY/30TH FLOOR FILE NO. 01231.
# STRUCTURES Analytical
Volume Asbestos Z o,5µ - Non- Area Analyzed Sensitivity Asbestos Concentration
(liters) Tvne(s) < sµ a 5µ Asbestos (mm') (S/cc) (S/mm') (S/cc)
89 1450.00 None Detected 0 0.0635 0.0042 <15.75 <0.0042
90 1450.00 None Detected 0 0.0635 0.0042 <15:75 <0.0042
91 1450.00 None Detected 0 0.0635 0.0042 <15.75 <0.0042
92 1450.00 None Detected 0 0.0635 0.0042 <15.75 <0.0042
93 1530.00 None Detected 0 0.0635 0.0040 <15.75 <0.0040
94 1610.00 None Detected 0 0.0635 0.0038 <15.75 <0.0038
NYC-WTC 000109412