NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn: Benjamin Sallemi Received: 10/3/02 4:00:00 PM
ATC Associates Inc. ATC Group #: 8932
104 East 25th Street Analysis Date: 10/4/02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-8280
Project: DEP Clean-up ATC Project #: 22906-0002
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
• by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Asb Type(s) O.Sp-S Sp (S/cc) (S/mm') (S/cc) Notes
04 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -1
05 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -2.
06 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -3
07 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -4
08 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -5
09 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -6
10 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8932 -7
MARK PEYSAKHOV MICHAEL A. GORYCKI, Ph.D.
Anal~zed by: 9pproved by:
Disclaimer. The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. Th is only responsible
foY data reported in structures/mm'. This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the U.S. Government This reports relates only to the samples reported above. Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request.
Accredited for NVLAP PLM/TEM #101187-0, NY State ELAP #10879
Page 1 of 2
NYC-WTC 000107933
OCR can misread numbers and units. Confirm readings against the page image before using them.