NYC 9/11 Public Portal Document
ATC Associates
104 East 25 Street, New York, NY 10010 w
Phone: (212) 353-8280 Fax: (212) 353-8306
Attn. Benjamin Sallerni Received: 930-02 8:00:00 Aft
_ATC Associates Inc. ATC Group #: 8914
104 East 25th Street Analysis Date: 9:30,02
New York NY 10010
Fax: (212) 353-3599 Phone: (212) 353-8280
Project: DEP Clean-up ATC Project #: 22906-0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non Asbestos # Structures Sensitivity Concentration
Sample Volume Analyzed Asb Types) 0.5f1-5 Su (S/cc) (S/mm') (S/cc) Notes
04 1800.00 0.0450 t) None Detected 0 0 0.0045 <22.24 <0.0048
8914 -1
05 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8914 --
06 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8914 -3
0' • 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8911 -4
08 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8911 -5
09 1800.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
5911 -6
0 1500.00 0.0450 0 None Detected 0 0 0.0048 <22.24 <0.0048
8914 - -
ROMAN PEYSAKHOV V1ICHAEL A. GORYCKI, Ph.D.
.-Analyzed by: roved by:
Discfatmer: The laboratory is not responsible for data reported in structures/cc, which is dependent on volume collected by non-laboratory personnel. This la niy responsible
for data reported in structures;mm', This report may not be reproduced, except in full, without written approval by ATC Associates Inc. This report may not be used to claim
product endorsement by NVLAP or any other agency of the J.S. Government. This reports relates only to the samples reported above. uuality control data tincludng 35%b
conficence :imits and laboratory and analysis accuracy and precision) is available upon reeuest.
Accredited for NVLAP PLWTEM ".101 '87-0. NY State ELAP 10879
Pggn 1 o/'
NYC-WTC 000107729