NYC 9/11 Public Portal Document
10/11/2002 16:32 FAX 212 353 8306 ATC 2004
Attn. Benjamin Sallerni Received: 10/9/02 S:0000 AM
ATC Associates inc. ATC Group N: 8946
104 East 25th Stree: Analysis Date: 10/11/02
New York NY 10010
Fax: (212) 353.3599 Phone: (212) 353-82S0
Project: DEP Clean-up ATC Project #: 22906.0002
125 Cedar Street, New York, NY
Asbestos Fiber Analysis by Transmission Electron Microscopy (TEM) Performed
by EPA 40 CFR Part 763 Final Rule (AHERA)
Analytical Asbestos
Area Non flsbesws # Structures Sensitivity Concentration
Sample Volu►ne .4naly rd Asb Type(s) 03µ-5 sy
(S/cc) (S/rnrn') (S/cc) Notes
A -8S-17 3840.00 0.1236 24 None Detected 0 0 0.0008 <8.09 <0.0003 cellulose -7 Strictures Gypsum .14
3946 .17 S:rucn.res
A-8S-18 3830.00 0.1236 33 CHRYSOTILE i 1 00006 16.18 0,0016 Cellulose - 3 Structures 3ypsum • 30
8946 -; Strictures
A-8S-19-- 3820.00 0.1236 28 None Deteced 0 0 0-0008 <8.09 <0,0008 Callulose .7 Structures, 31ass - 21 Structure
8946 -19
A-8S-20 3810.00 0.1236 17 None Detected 0 0 00008 <8.09 -c0.000S Celulose • 2 Structures. Gypsum -15
8946 -2C Structures
A-7N-21 38::0.00 0.1236 21 C✓iRYSOTILE 0 1 0.0008 8.09 0.0008 Cellulose • 5 Structures, Gypsum 16
8946 -21 Structures
A-7N-22 3810.00 0.1236 14 CHRYSOT;LE 1 7 0.0008 8.09 '0-0008 Celulose -4 Strictures, Gypsum - 8
8946 -22 Structures, Glass -2 Structure
A -7N-23 3800.00 0.1236 18 None Detected 0 0 0.0008 <8.09 <0.0008 Cellulose -2 Structures, Gypsum -16
8946 -?3 Sttuotures
A-7N-24 3790.00 0.1236 19 CHRYSOTILE 0 1 0,0008 8.09 0.0008 Cellulose -1 Structures, Gypsum • 18
8946 -2d Strictures
A-7N-2j 378000 0.1236 9 CNRYSCTI_E 0 1 0.0008 5.09 0.0008 Cellulose-' Structures, Gypsum -S Swetures
8946 -2S
NUCHAEL i4. GORYCKI, Ph.D.
MARK PEYSAKU10V
Analyzed Approved by:
Disclaimer. The laboratory not responsible for data
is
In structures/x, which Is depe^dent
reporter
collected by
on
volume
personnel. This lab onh resod t ible
non
-laboratory is
for data reported in struclu simm'. This report may not be reproduced, except in full, without writer. approval by ATC Associates in:. This report may not be used to claim
product endorsement by NVI.AP or any other agency of Cie U.S. Gcvemment. Ttiis repots relates only to the samples reported above, Quality control data (including 95%
confidence limits and laboratory and analysis' accuracy and precision) is available upon request
Accredited for NVLAP PLM/TEMM 0101187-0... NY State E- P 010879
3
Page
6
uj
2002
11.
October
Friday,
000107467
NYC-WTC
OCR can misread numbers and units. Confirm readings against the page image before using them.