NYC 9/11 Public Portal Document
Al C ASSOCIATES,INC
LI 104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
I Fax 212-353-8306
' REPORT DATE: 07-29-02
CLIENT: Taylor Environmental Group, Inc.
I PROJECT NAME: SCAIStuyvcsant HS
3rd Floor
I PROJECT NUMBER:
SAMPLED BY:
M477-15217/29881
Client
I SAMPLE DATE
DATE RECEIVED:
07-28-02
07-29-02
DATE ANALYZED: 07-29-02
I SAMPLE MEDIA:
ANALYSIS REQUIRED:
Air Samples
Method NIOSH 7082
I AN L IS SU TS
I SAMPLE
ID
BATCH
NO.
I SAMPLE DESCRIPTION LEAD
CONCENTRATION
DETECTION
LIMIT
z1 3) (jig/ms)
I 01 20726 Inside Room 313 Near Entrance to Hallway
<3.1 3.1
I 02
03
20726
20726
Inside Room 313 Near Entrance to Hallway
Field $lank
<3.9
<1.5 µg
3.9
1.5 µg
I 04
NOTE 1:
20726 Field Blank <1.5 µg 1.5 µg
THE REPORTING LIMIT (RL) IS 3.0 µg
I NOTE 2:
At the present time them are no regulatory levels or requirements for indoor airborne lead in area
samples. However. OSHA has
established an action level of 30 µg'm3 and a permissible cxposu= level (FEZ.) of 50 gghn3 for personal samples.
NOTE 3:
I Blank units are in }tg
CERTIFICATION AND SIGNATURES
I ANALYSIS PERFORMED BY: I
H REPORT PREPARED BY
ATC certifies that this report is an aceurstc and authentic report of results obtained from the laboratory analysis.
7 QUALITY ASSURANCE COORDINATOR:
LABORATORY DIRECTOR: , - /l( ,t!
P
H ATC is accredited by the New York State Department of Health Environmental Laboratory Approval Program (FLAP) and by the American
Industrial Hygiene Association (AIHA) to perform analysis of lead in paint. dust wipes. air and soil samples. (FLAP #10379), (AIHA #100229).
P
NYC-WTC 000107122