NYC 9/11 Public Portal Document
ATC ASSOCIATES,XNC
104 E 25th Street, 10th Floor
New York,NY 10010
TeL 212-353-8280
I Fax 212-353-8306
1
REPORT DATE: 07-29-02
I CLIENT:
Taylor Environmental Group, Inc.
SCA/Stuyvesant HS
I PROJECT NAME:
3rd Floor
M477-15217/29881
PROJECT NUMBER
SAMPLED BY: Client
07-28-02
SAMPLE DATE
07-28-02
DATE RECEIVED:
07-28-02
DATE ANALYZER:
I SAMPLE MEDIA:
ANALYSIS REQUIRED:
Air Samples
Method NIOSII 7082
I ANALYSIS ICES T• -
I SAMPLE
ID
ID
BATCIi
NO.
SA1tiIPLE DESCFTPTIQN
LEAD
CONCENTRATION
(.L8/m3)
DETECTION
LIMIT
(;Lzin )
4.4 3.4
01 20722 Inside Rm 301A by Entrance
5.9 3.4
Entrannee
02 20722 Inside Rm 303 by
4.0 3.4
I 03 20722 Inside Rm 305 by Entrance
Inside Rm 325 by Entrance
5.4 3.4
04 20722
4.4 3.6
Q5 20722 Inside Rm 301A by Entrance
<3.6 3.6
06 20722 Inside Rm 303 by Entrance
<3.6 3.6
Q7 20722 Inside Rut 305 by Entrance
<3.6 3.6
08 20722 Inside Rm 325 by Entrance
<1.5 µg 1.5 µg
09 20722 Field Blank
<1.5 yg 1.5 ug
10 20722 Field Blank
NOTE 1:
I THE REPORTING LIMIT (RL) IS
NOTE 2:
time chore
3.0 µg
are no tt gulacory levels or requin-ments for indoor sirbotne 1caclin oea
stsonal same e«K
' OSHA hus
At the present able expo ure level (PEI.. of 50 ltg!n A
catablished an action level of 30 µg/m' and a pcn
I NOTE 3:
Blank units are in µg
I .
NYC-WTC 000107120