NYC 9/11 Public Portal Document
ATC ASSOCIATES, NC
I 104 E 25th Street, 10th Floor
New York,NY 10010
TeL 212-353-8280
Fax 212-353-8306
I REPORT DATE: 07-29-02
Taylor Environmental Group, Inc.
LI CLIENT:
PROJECT NAME:
SCA/Stuyvesant HS
3rd Floor
L' PROJECT NUMBER:
M477-15217/29881
Client
I SAMPLED BY:
SAMPLE DATE 07-27-02
DATE RECEIVED: 07-27-02
I DATE ANALYZED: 07-27-02
Air Samples
SAMPLE MEDIA:
ANALYSIS REQUIRED: Method NIOSH 7082
I
ANATVSIS RESULTS
I SAMPLE BATCH SAMPLE DESCRIPTION
LEAD
CONCENTRATION
DETECTION
LIMIT
' ID NO. (lagrn3) (µt' m 3)
<3.1 3.1
01 20716 Inside Rm 325 Near Entrance to Hallway
I 02 20716 Inside Rm 327 Near Entrance to Hallway
<3.1
<3.1
3.1
3.1
03 20716 Inside Rm 335 Near Entrance to Hallway
I 04 20716 Inside Rm 337 Near Entrance to Hallway
<3.1
<3.1
3.1
3.1
05 20716 Inside Rm 339 Near Entrance to Hallway
I 06 20716 Inside Rm 325 Near Entrance to Hallway
Hallway
<4.2
<4.2
4.2
4.2
07 20716 Inside Rm 327 Near Entrance to
I 08 20716 Inside R.rn 335 Near Entrance to Hallway
<4.2
<4.2
4.2
4.2
09 20716 Inside Rm 337 Near Entrance to Hallway
<4.2 4.2
10 20716 Inside Rm 339 Near Entrance to Hallway
<I.5 µg 1.5 µa
ii 20716 Field Blank
I 12 20716 Ficid Blank
<1.S g 1.5 µs
NOTE t:
I THE REPORTING LIMIT (RL) IS 3.0 µg
NOTE 2: requirements for indoor airborne load in area samples.
However, OSHA as
At the present time there arc no regulatory levels or exposurelevel (PEL) of 50 µg(mt for personal samples.
established an action level of 30 µg/m3 and a permissible
I NOTE 3:
µg
Blank units are in
I .
NYC-WTC 000107118
OCR can misread numbers and units. Confirm readings against the page image before using them.