NYC 9/11 Public Portal Document
ATC ASSOCIATES, INC
I 104 E 25th Street, 10th Floor
New York, NY 10010
Tel. 212-353-8280
Fax 212-353-8306
I REPORT DATE: 08-01-02
7 CLIENT:
PROJECT NAME:
Taylor Enviroruncntal Group, Inc.
SCA/Stuyvesant HS
345 Chambers Street, NY
I PROJECT NUMBER M477-15217/29881
I SAMPLED BY:
SAMPLE DATE:
Client
08-01-02
DATE RECEIVED: OS-01-02
I DATE ANALYZED:
SAMPLE MEDIA:
08-01-02
Dust Wipe Sample
1 ANALYSIS REQUIRED: Method EPA 30501/420
ANALYSIS RESULTS
I SAMPLE BATCH SAMPLE DESCRIPTION LEAD
CONCENTRATION
DETECTION
LIMIT
ID NO.
I (11g/f) (lag/ )
W-01 20833 Rm 911 Ceiling Unitveat Air Dumper <9.0 9.0
I F/B-01 20833 Field Blank <9.0 µg 9.0 ag
FIB-02 20833 Field Blank <9.0 µg 9.0 µg
I NOTE 1:
THE REPORTING LIMIT (RL) IS 13.0 µg
I NOTE 2:
HUD Guidelines for final clearance dun wipe sampler Floor 40 µgi l=, endow sills 250 µg/ft',
Window wells 400 µg/ftr, Exterior surface: 800 µgat.
NOTE 3:
I Blank units are in µg
CERTIFICATION AND-SLG_NATURES
I <—,
ANALYSIS PERFORMED BY:_______ I
I REPORT PREPARED BY:
- ~
analysis.
,ETC ccrtific, that this report is an accurate and authentic report of results obtained from the laboratory
I QUALITY ASSURANCE COORDINATOR:
LABORATORY DIRECTOR
(ELAP) and by the American
ATC is accredited by the New York State Department of Health Environmental Laboratory Approval Program
ndustrial Hygiene Association (AI}L&) to perform analysis of lead in paint, dust wipes, air and soil samples. (EL.4P a l0$79), (AIHA #100229).
1
NYC-WTC 000106751
OCR can misread numbers and units. Confirm readings against the page image before using them.