NYC 9/11 Public Portal Document
L . l L. n33 U k_ iri .l .L ), 1.L N k-
I 104 E 25th Street, 10th Floor
New York, NY 10010
TeL 212-353-8280
I Fax 212-353-8306
I REPORT DATE: 08-01-02
CLIENT: Taylor Environmental Group, Inc.
I PROJECT NAME. SCA/Stuyvesant HS
345 Chambcs Street, NY
I PROJECT NUMBER- M477-15217129881
SAMPLED BY: Client
I SAMPLE DATE:
DATE RECEIVED:
07-31-02
03-01-02
DATE ANALYZED: OS-01-02
~J SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 305017420
I ANALYSIS RESULTS
I SAMPLE
ID
BATCH
NO.
SAMPLE DESCRIPTION LEAD
CONCENTRATION
DETECTION
LIMIT
(jrb/ ) (µS/a2)
I LWD-01 20822 Rm 60IA Ceiling Unitvent Duct 11.8 9.0
I LWD-02
FBL-1
20822
20822
Rm 615 Ceiling Unitvent 0- Duct
Field Blank
<9.0
<9.0 µg
9.0
9.0 ytg
I FBL-2 20S22 Field Blank <9.0 µg 9.0 µg
NOTE 1:
THE REPORTING LIMIT (RL) 1518.0 µg
NOTE 2:
HUD Guidelines for final clearance dust wipe samples: Floor 40 µg/ftl, Window sills 250 µg/&,
Window wells 400 irg/ft', Exterior surfaces 200
NOTE 3:
Blank units are is µg
CERTIFICATION AND SIGNATURES
ANALYSIS PERFORMED BY: rtil
REPORT PREPARED BY: i~
ATC cernfice that this report is an accurate and authentic report of results obtained from the tabor-to ' enalysis.
QUALITY ASSURANCE COORDINATOR: 2i 't'~
LABORATORY DIRECTOR: _I.j _—
Atnericatt
is accredited by the New York State Dcparmtcnt of Hmlth Environmental Laboratory Approval Program (FLAP) and by the
analysis of lead paint. dust wipe, air and soil samples. (Ei.AP #10379), (ALHA 4100229).
Industrial Hygiene Association (AIHA) to perform in