NYC 9/11 Public Portal Document
ATC ASSOCIATES, )INC
104 E 25th Street,10th Floor
New York, NY 10010
Tel. 212-353-8280
I Fax 212-353-8306
I REPORT DATE: 07-29-02
Taylor Envirotunental Group, Inc.
1 CLIENT:
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
I PROJECT NUMBER: M477-15217/29881
SA1'IPLED BY: Client
I
SAMPLE DATE: 07-27-02
DATE RECEIVED: 07-27-02
DATE ANALYZED: 07-27-02
I
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
I
U ANALYSIS RESULTS
SAMPLE
ID
BATCH
NO.
SAMPLE DESCRIPTION LEAD
CONCENTRATION
(µgift=)
DETECTION
LIMIT
(l+F/ )
I <9.0 9.0
LW-01 20698 Rm 907 Ceiling Unitvent Damper
I FBL-1 20698 Field Blank <9.0 µg
<9.0 µg
9.0 µg
9.0 µg
FAL-2 20698 Field Blank
I NOTE 1:
TAE REPORTING LIMIT (EL) IS 18.0 µg
NOTE 2:
I HtJD Guidelines for final clearance dust wipe samples: Floor 40 µg/ft,
Window wells 400 µgifts.
NOTE 3:
Exterior surfaces 800 flt.
Window sills 250 µg'ft.
Blank units arc in µg
I CERTIFLCATION AND SIGNATURES
I ANALYSIS PERFORMED BY:
fl
/'
~r
REPORT PREPARED BY:
obtained from the laboratory analysis.
ATC certifies than this report is on accurate and authentic report of results
QUALITY ASSURANCE COORDINATOR:
A
l i( -
' LABORATORY DIRECTOIL-
Environmental Laborntoty Approval Program (ELAP) and by the American
ATC is accredited by the New York Statc Dcpsrnnent of Health and soil samples. (ELAP i* i OS79), (AIIiA P100229).
industrial Hygiene Association (AIHA) to perform aeslysis of 'cad in paint. dust wipes, air
NYC-WTC 000106716
OCR can misread numbers and units. Confirm readings against the page image before using them.