NYC 9/11 Public Portal Document
ATC ASSOCIATES,INC
1 104 E 25th Street, 10th Floor
New York, NY 10010
Tel- 212-353-8280
Fax 212-353-8306
I REPORT DATE: 07-23-02
CLIENT: Taylor Environmental Group, Inc.
I PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
I PROJECT N1JMBER: M477-15217/29881
SAMPLED BY: Client
SAMPLE DATE 07-22-02
DATE RECEIVED: 07-22-02
DATE ANALYZED: 07-22-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050!7420
I ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
(llg/a 2) (µg/ft)
W-01 20559 Rm 638 North Sdie Left Univent (Back Wall) 9.7 9.0
W-02 20559 Rm 639 North Side Right Univent (Back 'Wrall) <9.0 9.0
r
W-03 20559 Rm 615B South Side Left !invent (Back Wall) <9.0 9.0
I W-04
W-05
20559
20559
Rm 615B South Side Right Univent (Back Wall)
Rm 636 North Side Right Univent (Back Wall)
<9.0
<9.0
9.0
9.0
W-06 20559 Rm 636 North Side Right Univcnt (Back Wall) <9.0 9.0
W-07 20559 Rm 627 South Side Right Univent (Back Wall) <9.0 9.0
W-08 20559 Ran 627 South Side Left Univent (Back Wall) <9.0 9.0
W-09 20559 Field Blank <9.0 µg 9.0 µg
I W-10 20559 Field Blank <9.0 µg 9.0 µg
I NOTE 1:
T E REPORTING LIMIT (EL) IS 18.0 µg
I NOTE 2:
HUD Guidelines for fins! clearance dust wipe samples: Floor 40 µg/ t', Window sills 250 µg(ft',
Window wells 40D µF1ft'. Extcrior surfaces 800 jag/ft.
I
NOTE 3
µg
Blank units arc in
I
NYC-WTC 000106683