ATC ASSOCIATES,INC
104 E 25th Street,10th Floor
New York, NY 10010
TeL 212-3538280
1 Fax 212-353-8306
REPORT DATE: 07-22-02
CLIENT: Taylor Environmental Group, Inc.
PROJECT NAME: SCA/Stuyvesant HS
345 Chambers Street, NY
7th Floor
I PROJECT NUMBER: M4 77-1 521 7/2 9SS1
SAMPLED BY: Client
rl
SAMPLE DATE 07-21-02
DATE RECEIVED: 07-21-02
r
DATE ANALYZED: 07-21-02
SAMPLE MEDIA: Dust Wipe Sample
I ANALYSIS REQUIRED: Method EPA 3050/7420
I ANALYSTS RESULTS
LEAD DETECTION
SAMPLE EATCI4 SAMPLE DESCRIPTION CONCENTRATION LIMIT
n
ID NO. (ulit 2) (,&,/ft')
<9.0 9.0
W-01 20523 Room #701 East Side Univent Back Wall
<9.0 9.0
W-02 20523 Room #70 IA East Side Univent Back Wall
9.0
W-03 20523 Room #705 South Side Right Univent Back Wall <9.0
<9.0 9.0
Eu-04 20523 Room #705 South Side Left Univent Back Wall
9.0
I W-05 20523 Room #707 South Side Univent Back Wall
<9.0
<9.0 9.0
W-06 20523 Room #709 South Side Left Univent Back Wall
Wall <9.0 9.0
W-07 20523 Room #709 South Side Right Univent Back
9.0 µc
u
<9.0 ftE
W-03 20523 Field Blank
9.0 µg
I W-09 20523 Field Blank
<9.0 µg
k NOTE 1:
THE REPORTING LIMIT (RL) IS I8.0 µg
NOTE 2: loor 40 µ og'tt, Window silts 250
HUD Guidelines for final clearance dust wipe samples: F
µgJtr,
Window wells 400 µr,,. /fr. Exterior surfaces 900 µd/ R'•.
I NOTE 3.
Blank units are inµg