NYC 9/11 Public Portal Document
A1(..AJJU'..k1lt ,LLU..
104 E 25th Street, 10th Floor
I New York, NY 10010
TeL 212-353-8280
I Fax 212-353-8306
I REPORT DATE:
CLIENT:
07-19-02
Taylor Hnvironmcntal Group, Inc.
I PROJECT NAME: SCAIStuyvesant HS
345 Chambers St., NY
I SAMPLED BY:
SAMPLE DATE
Client
07-18-02
DATE RECEIVED: 07-18-02
I DATE ANALYZED: 07-18-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQUIRED: Method EPA 3050/7420
ANALYSIS RESULTS
SAMPLE BATCH SAMPLE DESCRIPTION LEAD DETECTION
ID NO. CONCENTRATION LIMIT
1 (µg/It) (µ8/ftl)
LW-01 20467 Rm 940 North Side Left Univent Rear <9.0 9.0
LW-02 20467 Rm 940 North Side Right Univent Rear <9.0 9.0
LW-03 20467 Rm 839 SouthSide Left Univent Rear <9.0 9.0
LW-04 20467 Rm 839 South Side Right Univent Rear <9.0 9.0
LW-05 20467 Rm 837 South Side Left Univent Rear <9.0 9.0
1 LW-06 20467 Rm 837 South Side Right Unitvent Rcar <9.0 9.0
LW-07 20467 Rm 835 South Side Left Unitvent Rear <9.0 9.0
I LW-08 20467 Rm 835 South Side Right Univvent Rear <9.0 9.0
LW-09 20467 Rm 833 South Side Left Unitvent Rear <9.0 9.0
I LW-10 20467 Rm 833 South Sdie Right Unitvent Rear <9.0 9.0
LW-11 20467 Rm 829 South Side Left Unitvent Rear <9.0 9.0
I LW-12 20467 Rm 829 South Sidc Fight Utiitvcnt Rcar <9.0 9.0
FBL-13 20467 Field Blank <9.0 µg 9.0 µg
FBL-14 20467 Field Blank <9.0 µ9 9.0 µS
NOTE 1:
TIEIE REPORTING LIMIT (RL) IS 18.0 µg
NOTE 2:
HUD Guidelines for final eleatonee dust wipe samples: Floor 40 µg/82, Window sills 250 µgitt,
Window wells 400 µg/ft, Exterior Surfaces 300 µg/fe-
NOTE 3.
Blank utuu are in µg
NYC-WTC 000106655
OCR can misread numbers and units. Confirm readings against the page image before using them.