NYC 9/11 Public Portal Document
ATC ASSOCIATES,INC
104 E 25th Street,10th Floor
New York,NY 10010
TeL 212-353-8280
Fax 212-353-8306
REPORT DATE: 07-17-02
CLIENT: Taylor Env ronrnental Group. Inc.
PROJECT NAME: SCA/Stuvvesant HS
345 Chambers St., NY
SAMPLED BY: Client
SAMPLE DATE 07-16-02
DATE RECEIVED: 07-16-02
DATE ANALYZED: 07-16-02
SAMPLE MEDIA: Dust Wipe Sample
ANALYSIS REQLtIRED: Method EPA 3050/7420
4NALYSIS RESULTS
LEAD DETECTION
SAMPLE BATCH SAMPLE DESCRIPTION LIMIT
CONCENTLUTION
ID NO. (g/ft)
(µg/fe)
14.3 9.0
LW-01 20409 Rm 901 East Side Unitvent Rear
16.1 9.0
LW-02 20409 Rm 903 South Side Left Unitvent Rear
9.5 9.0
LW 03 20409 Rm 903 South Side Middle Unitvent Rear
12.0 9.0
LW-04 20409 Rm 903 South Side Right Unitvent Rear
12.7 9.0
LW-OS 20409 Rm 907 South Side Unitvent Rear
15.8 9.0
LW-06 20409 Rm 911 South Side Left Unitvent Rear
Rm 911 South Side Right Unitvent Rear 30.3 9.0
LW-07 20409
Field Blank <9.0 µg 9.0 ug
FBL-1 20409
r rSL-2 20409 Field Blank <9.0 µ0 9.0
NOTE 1:
THE REPORTING LIDIIT (RL) IS 18.0 }tg
NOTE 2.
µg/ft', Window sills 25 µg1ft .
HUD Guidelines for final clearance dust wipe samples: Floor40
Window wells 400 µgift'. E•xtetiorsurfaces SO0 µg/ft'.
NOTE 3:
Blank units are in µg
NYC-WTC 000106645