NYC Law Department release
Independent mirror · updated as the City releases more · v1.3.3
☕ Buy me a coffee
← Document results/DEP Box 37/250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway
Document / 62 pages

Lead clearance sampling chain of custody, 250 Broadway, Sept 2001

Machine-extracted title · confidence 90%

Chain of custody documentation for lead dust wipe samples collected at 250 Broadway in September 2001.

NYC-WTC_000106015–000106076

Folder label: “250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway”

Page image
Scanned page image, NYC-WTC_000106031
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sep-18-01 3:45PM; - Page 8 212 727 7181; Sent By: IMA; 2126793114 IMA; rage Fteeeived: 9/16/01 1:00PM: P.03/05 2126793114 TO 7"'""'181 SEP 18 2801 14:05 FR SC'— 'TlFIC LABS

SCIEF TIFIC LAeORAWR ", INC. • 117 EAST 30Th STREET • NEW YORK NY 10018 679-9392 TEL: (212) 679-8600 • FAX: (212) rar cssxrraamaorair8W=twroa4Toxar

Date Received: 09/18/2001 SdLeb Job#: 201092212 Date Analyzed: 09/18/2001 Lead Analysis Results Dust Wipes EPA Method 305017420 Independent Monitoring & Analysis, Inc.. NewYork, NY Job Site: 201180; 250 Broadway Associates Area Lead Sample Scilab # Ciirnt (t12) (4m) Number Loeati al 201092212 1,261- 1 01 201180-78 8th Floor North Fan Rm Post Coil Room Floor 1 .53 02 201190-79 8th Floor North Fan Rm Coil Rm Floor 1 <25 03 201180.80 8th Floor North Fan Rm Pipe CoiVFilter Rm Floor 1 <25 Mixh►g Chamber 04 201180-81 8th Floor North Fan Rm Middle 1 73 05 201180.82 8th Foor North Fan Rm Right Mixing Ctataber 113 ' 06 201180-83 8th Floor North Fan Rnlbrip Pan Rm floor (post coil) 1 1 107 07 201180-84 8th Floor North Fan Rm Coil Rm floor 1 57 08 201180.85 8th Floor North Fan Rm Filter Rm Floor 1 <25 09 201180-86 8th floor North Fan Rm Pro-Coil Rm floor 1 61' 10 201180-87 8th Floor North Pan Rm Mixin9 Chamber floor I <25 C!>ambcrFloor 11 201180-88 8th Floor South Fan Rm LfL Mtxing 1 33 12 201180.89 8th Floor South Fan Rm 1.tt. Mixing Chamber Floor 1 d5 13 201180.90 8th Floor South Fan Rm Coil Rm Floor 1 9() 14 201180-91 8th Floor South Pan Rm Post Coil/Drip Pan Rm floor 1 30 15 201180-92 8th Floor South Fan Rm Middle Muting Chamber 1 60a 16 201180-93 8th floor South Fan Rm Filter Rm 1 29 17 201180-94 8th Floor South Fan Rm Coil Rm Floor 1 737' Floor 18 201180-95 8th floor South Pan Rm Plge Coll ilta Rm 1 <25 8th Floor South Fan Rm Right Mixing Chamber Floor 19 201180.96 1 96 20 201180-97 19th floor North Pan Rm Coll Rm floor 1 28 21 201180-98 19th Floor North Fan Rm Hire Rm Floor 1 36 22 201180-99 19th Floor North Fur Rm Mbdng Chamber Floor 92 23 201180-100 19th Floor North Fan Rm Pr+e-CoilMrip Pan Rm Floor 1 <25 24 201180-101 19th Ploar North Pan Rm Coil Rm Floe ~, f

Reviewed by; 1110879. These samples were subcontracted to ATC. FLAP

Analyzed by:

Page 1 of 3 ELAP No: 11480 AL5ANY •iUCHM0ND NEW YORK • LOS ANO.aES • 8051011•

NYC-WTC 000106031

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000106031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →