NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 37/250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway
Document / 62 pages

Lead clearance sampling chain of custody, 250 Broadway, Sept 2001

Machine-extracted title · confidence 90%

Chain of custody documentation for lead dust wipe samples collected at 250 Broadway in September 2001.

NYC-WTC_000106015–000106076

Folder label: “250 BROADWAY; Block: 124 Lot: 24 BIN: 1001408 245 Broadway, 2-4 Murray St. 1-7 Park Pl, 239- 247 Broadway

Page image
Scanned page image, NYC-WTC_000106031
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Sep-18-01 3:45PM; - Page 8 212 727 7181; Sent By: IMA; 2126793114 IMA; rage Fteeeived: 9/16/01 1:00PM: P.03/05 2126793114 TO 7"'""'181 SEP 18 2801 14:05 FR SC'— 'TlFIC LABS

SCIEF TIFIC LAeORAWR ", INC. • 117 EAST 30Th STREET • NEW YORK NY 10018 679-9392 TEL: (212) 679-8600 • FAX: (212) rar cssxrraamaorair8W=twroa4Toxar

Date Received: 09/18/2001 SdLeb Job#: 201092212 Date Analyzed: 09/18/2001 Lead Analysis Results Dust Wipes EPA Method 305017420 Independent Monitoring & Analysis, Inc.. NewYork, NY Job Site: 201180; 250 Broadway Associates Area Lead Sample Scilab # Ciirnt (t12) (4m) Number Loeati al 201092212 1,261- 1 01 201180-78 8th Floor North Fan Rm Post Coil Room Floor 1 .53 02 201190-79 8th Floor North Fan Rm Coil Rm Floor 1 <25 03 201180.80 8th Floor North Fan Rm Pipe CoiVFilter Rm Floor 1 <25 Mixh►g Chamber 04 201180-81 8th Floor North Fan Rm Middle 1 73 05 201180.82 8th Foor North Fan Rm Right Mixing Ctataber 113 ' 06 201180-83 8th Floor North Fan Rnlbrip Pan Rm floor (post coil) 1 1 107 07 201180-84 8th Floor North Fan Rm Coil Rm floor 1 57 08 201180.85 8th Floor North Fan Rm Filter Rm Floor 1 <25 09 201180-86 8th floor North Fan Rm Pro-Coil Rm floor 1 61' 10 201180-87 8th Floor North Pan Rm Mixin9 Chamber floor I <25 C!>ambcrFloor 11 201180-88 8th Floor South Fan Rm LfL Mtxing 1 33 12 201180.89 8th Floor South Fan Rm 1.tt. Mixing Chamber Floor 1 d5 13 201180.90 8th Floor South Fan Rm Coil Rm Floor 1 9() 14 201180-91 8th Floor South Pan Rm Post Coil/Drip Pan Rm floor 1 30 15 201180-92 8th Floor South Fan Rm Middle Muting Chamber 1 60a 16 201180-93 8th floor South Fan Rm Filter Rm 1 29 17 201180-94 8th Floor South Fan Rm Coil Rm Floor 1 737' Floor 18 201180-95 8th floor South Pan Rm Plge Coll ilta Rm 1 <25 8th Floor South Fan Rm Right Mixing Chamber Floor 19 201180.96 1 96 20 201180-97 19th floor North Pan Rm Coll Rm floor 1 28 21 201180-98 19th Floor North Fan Rm Hire Rm Floor 1 36 22 201180-99 19th Floor North Fur Rm Mbdng Chamber Floor 92 23 201180-100 19th Floor North Fan Rm Pr+e-CoilMrip Pan Rm Floor 1 <25 24 201180-101 19th Ploar North Pan Rm Coil Rm Floe ~, f

Reviewed by; 1110879. These samples were subcontracted to ATC. FLAP

Analyzed by:

Page 1 of 3 ELAP No: 11480 AL5ANY •iUCHM0ND NEW YORK • LOS ANO.aES • 8051011•

NYC-WTC 000106031

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000106031Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →