NYC 9/11 Public Portal Document
Safe Environmental Consultants, Inc.
448 Neptune Avenue,Suite 22H.Brooklyn,N.Y. 11224 +Tel.:(718)372-4094 +Fax:(718)372-7076
571416 Avenue, Brooklyn,N.Y. 11219 +Tel.:(718)437-5331 + Fax.(718)437-5332
AIR SAMPLES ANALYTICAL REPORT
Date Collected: 03/02/2002 Client:
Collected By: A. Uwagboe Shire Realty Corp.
but It"w4vod. 03/02/2002
Date Analyzed: 03/02/2002
Analyzed By., ,. nlo14
Signat ure:
Analytical Method: NTOSf7400
NYS DOH 11LAP LAB #: 11716
RE:5 Beelanan Streit, New Yo& NY
Air Quality
CPN:0203-5B
Client Sample Location Sample Volume Fibers per
Sample t♦ Description (Liters) (cc/m&)
0203-5-0l Roof Top,10th Floor Air Quality 990 0.0035 floc
0203-513-02 l0d` Floor, Main Office, Left Window Air Quality 990 0.0020 fYcc
0203-5B-03 10°` Floor. Main Office, West Side, Window Left Air Quality 960 0,0020 Ike
0203-SB-04 9'" Floor, Room #92. West Side, Window #1. Left Air Quality 1110 0.0022 Uoc
0203-SB45 0`h Floor, Room #92, West Side, Window #2, Middle Air Quality 1080 0.0023 tyce
0203-SB-06 9'" Floor, Room #92. West Side, Window #3, Right Air Quality 1080 0.002317e4
0203-5B.07 3"t Floor. Room #314, West Sid*, Window #1, Right Air Quality 1140 0.0017 floc
0203-5B.08 3'd Floor, Room #314, West Side, Window #2, Center Air Quality 1140 0.0022 000
0203-S1-09 3'd Floor. Roam #314, W`at Side, Window #3, Left Air Quality 1065 0.0018 Voc
0203-5B-T0 7th Floor, Room 11720, West Side, Window Left Air Quality 1200 0.0020 Vac
0203-SB-11 i°' Floor, Room #720, Want Side, Window Right Air Quality 1155 0.0021 flea
0203-SB-12 7" Floor, Room #720, West Side, Window Middle Air Quality ' 1160 0,0021 Ike
Please stow that the NIOSII 7400 Method ushss Phase Coemaa Miaosoogy bus all Sbara and does not distlaatigh aabealos Share alone.
Ghost supplied the votunta. Results Applicable to these items tooted. Liability limited to the coat of aaatyats.
TWA- laada Work Area, OWA-Ouoside Work Area, BOL-Below Botaetthla Limits
Page 1 oft
TT0'd OZ00# 0 7 XVMCV0>3S OUT 6L60b652TZ 25:TT 2002.8T - liVW
NYC-WTC 000105329
OCR can misread numbers and units. Confirm readings against the page image before using them.