J Hillmann Environmental Co.. Inc. Office:

PRE-ENCAPSULATION/FINAL INSPECTION Date: Address: O —i0P GI'Qi{J'lyl IS+ Project Mgr. 1Q_' Area: r t- - L / 1 f LF'd /?aQl( f ' F IMA. Job #: 361 PRE-ENCAPSULATION

Yes No NLê () () A 12-hour waiting period allowed between the 1st final cleanings. () () () Initial wet cleaning performed properly. - () () () Negative Sir filtration units operating. •.

() All polyethylene off walls and flos4ccept for critical barriers and decon. () () () () ()

No visible debris between and beams. () () () No visible debris behi c10 of perimeter columns. () () () No visible debris op of ducts. () () () No visible de on hangers, rods, lights, etc. () () No vis ebris on top of decor. () () () Noj4a16te debris behind convectors. () () () bags and waste removed from the work area. () () All non-essential equipment out of area. () () All remaining equipment clean, including under the negative air filtration devices. () () () Encapsulant available for use. grand Number Name

Pass( Fall( )

FINAL INSPECTION

I Yes No o IL A 2nd & 3rd final cleaning performed with a four hour waiting period between time. I (j (Y -Ali polyethylene off walls and floors except for critical barriers and decon. Area thoroughly encapsulated. () Area free of residual dust. 1 () () () Negative air filtration units sufficient for a minimum of two air changes per hour. Area free of debris missed due to being under removes! polyethylene. Inspection performed with a flashlight or temporary lighting. final () No visible Wols of water/encapsulation or condensation for at least one hour after or enpa ülation.

NYC-WTC 000105010

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000105010Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →