NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 36/69 GOLD STREET
Document / 12 pages

Dust sampling report for NYU Downtown Hospital, Sep 2001

Machine-extracted title · confidence 50%

Report detailing dust sampling from hospital entrances to determine asbestos content following the September 11 attacks.

NYC-WTC_000104679–000104690

Folder label: “69 GOLD STREET

Page image
Scanned page image, NYC-WTC_000104686
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

INDOOR AIR QUALITY ANALYSIS NYU DOWNTOWN HOSPITAL 9/18/01

Location U/m3 CO2 CO RH Tem . Dew Point

B39 88.9 455 2.1 2C-General 59.1 540 1.9 43.0 45.1 75.6 J 51.6 73.3 50.7 2C-OR #3 57.8 439 1.7 51.8 69.1 50.6 2A-Eye Clinic 81.6 433 1.6 48.0 70.9 50.3 2B-Minor 71.9 578 1.6 49.2 71.0 51.0 Procedures 6C-OR 58.3 547 1.6 50.2 71.7 52.1 6C-Nursing 59.5 551 1.6 49.9 71.9 52.2 6C-603 63.1 540 1.6 45.3 70.7 50.3 5C-514 75.3 595 1.6 48.0 72.8 52.0 4C-415 78.8 680 1.6 46.3 74.5 52.6 4C-410 74.7 595 1.7 43.5 75.6 51.8 3C-ICU-316 63.5 520 1.7 43.9 75.3 51.8 G-ERTransition 68.2 443 1.7 50.3 72.7 53.1 G-ER-Trauma 67.1 444 1.6 54.5 70.7. 53.5 G-ER-Chest Pain 84.3 590 1.7 56.1 70.6 54.3 GERMain 97.4 751 1.9 54.4 72.3 54.9 Ambient 144.6 364 1.6 39.2 81.8 55.8

ug/m3=micrograms per cubic meter Standard= 15,000 ug/m3 CO2 arbon Dioxide Standard= 1,000 Parts Per Million (PPM) CO= Carbon Monoxide Standard= 0-9 PPM RH= Relative Humidity Standard= 30-50% Temp.= Temperature Standard= 68-84° Fahrenheit

200I NY4000I

NYC-WTC 000104686

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000104686Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000104673 · Box DEP Box 36

Report from Consulting & Testing Services, Inc. regarding air quality monitoring at NYU Downtown Hospital in September 2001.

Filed in the same folder

Compare copies and versions →