ASBESTOS FIBER ANALYSIS BY TRANSMISSION ELECTRON MICROSCOPY (TEM)
With Fiber Identification by Selected-Area Electron Diffraction (SAED) and Energy-Dispersive X-RAY Spectroscopy (EDS;
Method: AHERA Final Rule. EPA Federal Register (40 CFR. Part 763), Vol 52, No. 210, October 30, 1987
Sample Identification Analysis Parameters
Project/Site: Tribeca Towers, 105 Duane St., NY, NY TEM Sample No.: 5771 - 62574
Various Sites
Date Received: 10/26/01 Grid Openings Analyzed: 6
Project Sample No.: 10 Average Grid Opening: 106.00 um
Air Volume: 1300 liters Total Area Analyzed: 0.0674 mm2
Filter Type: MCE 25 mm diam. , Pore Size: 0.45 um Analytical Sensitivity: 14.8 s/mm2
Effective Area: 385 mm2 0.0044 s/cc
----------------------------------------------------------------------------------------------------------------------------------
FIBROUS PARTICULATES ANALYZED
Number Observed CONCENTRATION
Total
Single Matr,-x Total. Struct. Filter Air
Fibers Bundles Clusters Struct. Struct. >=5um Struct/mm2 Struct/cc ngm/m3
Chrysotile Asbestos 1 0 0 0 1 0 14.8 0.0044 145
Amphibole Asbestos 0 0 0 0 0 0 00 0.0000 0
Ambiguous 0 0 0 n 0 0 0.0 0.0000 0
Total asbestos (includes ambiguous structures) 1 0 14.8 0.0044 145
Non-Asbestos 0 0 0 0 0 0 0.0 0.0000 N/A
No Identification 0 0 0 0 0 0 0.0 0.0000 N/A
Totals (All Structures) 1 0 14.8 0.0044 N/A
The estimated uncertainty of this analysis is 1 standard deviation.
----------------------------------------------------------------------------------------------------------------------------------
' Non-asbestos fiber i.d. (EDS/SAED): None detected
Amphibole Asbestos Type: None detected
----------------------------------------------------------------------------------------------------------------------------------
The Analysis was carried out in accordance with the approved TEM method.
This laboratory is in compliance with the quality specified for the method.
I Analyzed by: Report Reviewed by:
Marek Peysakhov Michael A. Gorycki, Ph.D.
Director of Electron Microscopy
NYC-WTC 000104359