NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 36/No folder label
Document / 118 pages

Final air sample results, 55 Church Street, undated

Machine-extracted title · confidence 90%

One-hundred-eighteen page document from Testwell Laboratories presenting final air sample results for a lease at 200 Park Avenue.

NYC-WTC_000103604–000103721
Page image
Scanned page image, NYC-WTC_000103692
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

L TESTWELL LABORATORIES, INC. -I_i Environmental Laboratory 47 Hudson Street, Ossining, New York 10562 NYS ELAP * 11142 NVLAP # 200083.0 AIHA # 100147

Transmission Electron Microscopy Results Client: Bovis Lend Lease - LMB 200 Park Avenue New York, New York Date Collected: 08/21/02 Date Rec'd (lab): 08/22/02 Sample Location: Millenium Hilton Hotel @ WTC Various Floors Analysis Date: 08/23/02 55 Church Street TEM Analyst: D. McCarl New York, New York Analytical Method: AHERA Field Technician: B. Gitman Filter Type: MCE 0.45 micron 1vg.Grld Opening: 0.0121mm2

Sample #: Sample Lab Number Volume Coll. i Openings Grid Grid Area Countable Asb Concentration Concentration Location: 02TEM # Analyzed Structures Structures/mm2 Structures/cc liters Anal ed

371 Pits of freight elevator 6948 1280.0 6 0.073 0 <13.77 <0.004 372 Level SC, C, L 6949 1280.0 6 . 0.073 0 <13.77 <0.004 373 Level SC, C, L 6950 1280.0 6 0.073 0 <13.77 <0.004 374 Level SC, C, L 6951 1280.0 6 0.073 0 <13.77 <0.004 375 Level SC, C, L 6952 1280.0 6 0.073 0 <13.77 <0.004 376 Blank 6953 N/A 6 0.073 0 <13.77 <0.004 377 Blank 6954 N/A 6 0.073 0 <13.77 <0.004 Structures/mm2 Structures/cc Total Average Concentrations < 13.77 < 0.004 Thi c nn.t is fhe.......................................... . . . . . . .. .

- -••~••w• • • • aua,ra,yi aNL„ L ai ian nUL ue use oy the cuent to ciaim product Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. endorsement by the National The laboratory has no control over air sampling collection. This certificate of analysis/report shall not be reproduced in full, without the written approval of Testwell Laboratories, Inc.

• Laboratory Director/Approved Signatory

NYC-WTC 000103692

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103692Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →