NYC 9/11 Public Portal Document
S
I-
• L TESTWELL LABORATORIES, INC.
Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYS EIAP # 11142
NVLAP # 200083-0
AIHA # 100147
Transmission Electron Microscopy Results
Client: Bovis Lend Lease - LMB
200 Park Avenue
New York, New York Date Collected: 08/08/02
_ Date Rec'd (lab): 08/09/02
• Sample Location: Millenium Hilton Hotel @ WTC Various Floors Analysis Date: 08/12/02
55 Church Street TEM Analyst: D. McCar/
New York, New York Analytical Method: AHERA
Field Technician: B. Gitman
Filter Type: MCE 0.45 micron
• vg.Grid Opening: 0.0121mm2
Volume Grid
Lab Number Grid Area Countable Asb. Concentration Concentration
Sample #: Sample Location: Coll, Openings
02TEM # (liters) Analyzed Structures Structures/mm2 Structures/cc
Apelyed
56th Floor Inside Work
348 6191 1280.0 6 0.073 0 <13.77 <0.004
Area
56th Floor Inside Work
349 6192 1280.0 6 0.073 0 <13.77 <0.004
Area
56th Floo Inside Work
350 6193 1280.0 6 0.073 2 27.55 0.008
56th Floor Inside Work
351 6194 1280.0 6 0.073 0 <13.77 <0.004
1S
352
56th Floor Inside Work
Ar
6195 1280.0 I 6 0.073 0 <13.77 <0.004
33rd Floor Inside 6196 ,280.0 6 0.073 0 <13.77 <0.004
353
Work Area
•
354
33rd Floor Inside
Work Area
6197 1280.0 I 6 0.073 0 <13.77 <0.004
Structures/mm 2 Structures/cc
Total Average Concentrations 15.74 0.005
This report is the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National
Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government The laboratory has no control over air sampling collection. This
certificate of analysis/report shall not be reproduced in full, without the written approval of Testwell Laboratories, Inc.
Laboratory Director/Approved Signatory
NYC-WTC 000103685