NYC Law Department release
Independent mirror · updated as the City releases more · v1.2.6
← Document results/DEP Box 36/No folder label
Document / 118 pages

Final air sample results, 55 Church Street, undated

Machine-extracted title · confidence 90%

One-hundred-eighteen page document from Testwell Laboratories presenting final air sample results for a lease at 200 Park Avenue.

NYC-WTC_000103604–000103721
Page image
Scanned page image, NYC-WTC_000103641
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

I1 LL TESTWELL LABORATORIES, INC. Environmental Laboratory 47 Hudson Street, Ossining, New York 10562 NYS ELAP # 11142 NVLAP # 200083-0 AIHA # 100147

Transmission Electron Microscopy Results •

Client: Bovis Lend Lease - LMB 200 Park Avenue New York, New York Date Collected: 06/11/02 Date Rec'd (lab): 06/12/02 _ • Sample Location: Millenium Hilton Hotel @ WTC Various Floors Analysis Date: 06/14/02 55 Church Street TEM Analyst: D. McCarl New York, New York Analytical Method: AHERA Field Technician: B. Gitman Filter Type: MCE 0.45 micron vg.Grid Opening: 0.0121mm2 •

Sample #: sample Location: 1 Lab Number 02TEM # Volume Coll. (liters) Grid

OpeningsI Analyzed I Grid Area Countable Asb. Concentration Analyzed Structures Structures/mm2 Concentration Structures/cc

Inside Work Area 147 2880 1280.0 6 0.073 0 <13.77 <0.004 37th Floor Inside Work Area 148 2881 1280.0 6 0.073 0 <13.77 <0.004 37th Floor Inside Work Area 149 2882 1280.0 6 0.073 0 <13.77 <0.004 37th Floor Inside Work Area 150 2883 1280.0 6 0.073 0 <13.77 <0.004 37th Floor Inside Work Area 151 2884 1280.0 6 0.073 0 <13.77 <0.004 37th Floor

152 Blank 2885 0.0 6 0.073 0 <13.77 <0.004

153 Blank 2886 0.0 ( 6 0.073 0 <13.77 <0.004

Structures/mm2 Structures/cc Total Average Concentrations <13.77 <0.004 This report is the confidential property of our clients. This certificate of analysis:report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. The laboratory has no control over air sampling collection. This • certificate of analysis/report shall not be reproduced in full, without the written aoproval of Testwell Laboratories, Inc.

Laboratory Director/Approved Signatory

NYC-WTC-000103641

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103641Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →