Document / 118 pages

Final air sample results, 55 Church Street, undated

Machine-extracted title · confidence 90%

One-hundred-eighteen page document from Testwell Laboratories presenting final air sample results for a lease at 200 Park Avenue.

NYC-WTC_000103604–000103721
Page image
Scanned page image, NYC-WTC_000103626
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

lb TESTWELL LABORATORIES, INC. Environmental Lat oratory NYS aAP 511142 47 Hudson Street, Ossining, New York 10562 N W a 200087-0 • AIHA 7 100147

Transmission Electron Microscopy Results client: Bovis Lend Lease - LMB • 200 Park Avenue New York, New York Date Collected: 06/03/02 Date Rec'd (lab): 06/04/02 Sample Location: Millenium Hilton Hotel @ WTC Various Floors Analysis Date: 06/05/02 55 Church Street TEM Analyst: D. McCar/ New York, New York Analytical Method: AHERA • Field Technician: B. Gitman Filter Type: MCE 0.45 micron vg.Grid Opening: 0.0121mm2 Volume Grid Lab Number Grid Area Countable Asb. Concentration Concentration Sample #: Sample Location: Coll. Open'r s 02TEM # Analyzed Structures Structures/mm2 Structures/cc (liters) Openi Analyced •

Inside Work Area 90 2721 1280.0 6 0.073 0 <13.77 <0.004 41st Floor Inside Work Area 91 2722 1280.0 6 0.073 0 <13.77 <0.004 41st Floor Inside Work Area 92 2723 1280.0 6 0.073 0 <13.77 <0.004 •

41st Floor Inside Work Area 93 2724 1280.0 6 '" 0.073 0 <13.77 <0.004 41st Floor Inside Work Area 94 2725 1280.0 6 0.073 0 <13.77 <0.004 41st.Floor Inside Work Area •

95 2726 1280.0 6 0.073 0 <13.77 <0.004 42nd Floor Inside Work 96 Area 2727 1280.0 6 0.073 0 <13.77 <0.004 42nd Floor 97 Inside Work Area 2728 1280.0 6 0.073 0 <13.77 <0.004 42nd Floor Inside Work Area •

98 2729 1280.0 6 0.073 0 <13.77 <0.004 42nd Floor Inside Work Area 99 2730 1280.0 6 0.073 0 <13.77 <0.004 42nd Floor Structures/mm2 Structures/cc • Total Average Concentrations <13.77 <0.004 This report Is the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States GovemrnenL The laboratory has no control over air sampling collection. This certificate of analysis/report shall not be reproduced In full, without the written approval of Testwell Laboratories, Inc.

• Laboratory Director/Approved Signatory

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103626Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →