Final air sample results, 55 Church Street, undated

Machine-extracted title · confidence 90%

One-hundred-eighteen page document from Testwell Laboratories presenting final air sample results for a lease at 200 Park Avenue.

NYC-WTC_000103604–000103721
Page image
Scanned page image, NYC-WTC_000103617
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

.4

TESTWELL LABORATORIES, INC. Environmental Laboratory rrrs Euv # 11142 47 Hudson Street, O{sfning, New York 10562 NVLAP # 200083.0 AIF1A # 100147

Transmission Electron Microscopy Results Client: Bovis Lend Lease - LMB 200 Park Avenue New York, New York Date Collected: 05/24/02 • Date Rec'd (lab): 05/26/02 Sample Location: Millenium Hilton Hotel @ WTC (Various Floors) Analysis Date: 05/28/02 • 55 Church Street TEM Analyst: D. McCar/ New York, New York Analytical Method: AHERA

Field Technician: T. Chhetry — _ _ • Filter Type: MCE 0.45 micron vg.Grid Opening: 0.0121mm2 Volume Grid Lab Number Grid Area Countable Asb. Concentration Concentration Sample #: Sample Location: Coll. Openings 02TEM # (liters) Analyzed Structures Structures/mm) Structures/cc Analyzed

Inside Work Area 1280.0 6 0.073 0 <13.77 <0.004 49 2457 48th Floor

50 Inside Work Area 48th Floor 2458 1280.0 I 6 0.073 0 <13.77 <0.004

51 Inside Work Area 48th Floor 2459 1280.0 I 6 0.073 0 <13.77 <0.004

52 Inside Work Area 47th Floor 2460 1280.0 I 6 0.073 0 <13.77 <0.004

53 Inside Work Area 47th Floor 2461 1280.0 I 6 0.073 0 <13.77 <0.004

Inside Work Area 2462 1280.0 6 0.073 0 <13.77 <0.004 54 47th Floor Inside Work Area <13.77 <0.004 55 2463 1280.0 6 0.073 0 47th Floor i 56 Inside Work Area 47th Floor 2464 1280.0 I 6 0.073 0 <13.77 <0.004

57 Field Blank 2465 0.0 6 0.073 0 <13.77 <0.004

58 Field Blank 2466 0.0 6 . 0.073 0 <13.77 <0.004 Structures/mm2 Structures/cc Total Average Concentrations N/A N/A • This report Is the confidential property of our clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary Laboratory Approval Program (NVLAP) or any agency of the United States Government. The laboratory has no control over air sampling collection. This certificate of analysis/report shall not be reproduced in full, without the written approval of Testwell Laboratories, Inc.

Laboratory Director/Approved Signatory

i

NYC-WTC 000103617

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000103617Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Page similarity is temporarily unavailable or this page has no indexed vector.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →