Regarding: Microvac Testing for Asbestos Fibers
Millennium Hilton Hotel
55 Church Street, NY, NY
• Certifications &
Accreditation Dear Mr. Egan,
Testing of various surfaces within kitchen and food preparation areas of the
Millennium Hilton Hotel was conducted as per your request.
Attached, please find a summary of results indicating location of sample, surface
sampled, results reported in number of asbestos structures observed and the
calculated concentration of asbestos fibers per square centimeter.
ISO 9001 CERTIFIED
Please note that this method of analysis is highly sensitive and the mere
presence of asbestos fibers does not represent that the surface sampled is
•
contaminated. Background asbestos fiber concentrations range from 3,000 to
NvLAp~ 5,000 asbestos structures per square centimeter.
Based on sample results, the following CFA items were determined to be
NVLAP LAB CODE 200083-0
contaminated with asbestos fibers and require cleaning or disposal:
CFA # 9 - 3`d Floor Kitchen Ice Machine — Top of unit and interior
CFA# 11 — 3d Floor Kitchen Pass-thru Refrig. — Top of unit
SM CFA # 18 — 3`d Floor Kitchen Freezer — Top of unit and interior
CFA #18A — 3rd Floor Kitchen Dual Temp. Refrig. — Top of unit
• AASHTO R18 All other surfaces sampled were at method detection limit or below.
Respectfully,
NYS DOH ELAP #10871, Testwell Laboratories, Inc.
11142& 11651
•
res Sc u g
Vice Presi
Cc: Michael Deane/BLL
•
~V~ Sharon Flynn/BLL
Testwell Laboratories. Inc.
Ossining, NY is accredited
by the American Industrial
Hygiene Association (AIHA)
in Ste industrial hygiene program
CERT NO. 100147
•
NYC-WTC 000103717
OCR can misread numbers and units. Confirm readings against the page image before using them.