NYC 9/11 Public Portal Document
•
L TESTWEL _ABORATORIES, INC.
Environmental Laboratory NYS ELAP s 11142
47 Hudson Street, Ossining, New York 10562 N' WPa2coca3-o
AIHA # 100147
P-CM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/13/02
Date Rec'd (lab): 02/14/02
Project #: MBO-025AB Analysis Date: 02/14102
Analyst: D. Agarest
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
• New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location: I Sample
Type
Work
Location
02PCM # Volume
—
Duration Concentration
(min.) f/cc
Michael_Carispn_._._ Personal 19th - 22nd
7Pers -~ 2715 75 30 0.0360
PH STEL Floors
Michael Carlson Personal 19th - 22nd
8Pers --------------pii 2716 288 120 0.0572
- TWA Floors
Michael Carlson Personal 19th -22nd
17Pers 2725 276 120 0.0416
PII TWA Floors
20 Blank Blank N/A 2728 0 0 N/A
21 Blank Blank N/A 2729 0 0 N/A
i
Total Duration Sampled (min.) 270
Short Term Exposure Limit (STEL) 0.0360
8 hr. Time Weighted Average (TWA) 0.027C
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, cr
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
• * Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory CC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCarl - Laboratory Director
NYC-WTC 000103561
OCR can misread numbers and units. Confirm readings against the page image before using them.