L
NYC 9/11 Public Portal Document
I t51 WLLL-LABUKAi UKItS, ING.
11L Environmental boratory
47 Hudson Street, Ossining, New York 10562
NYS ELAP # 11142
NVLAP 4 200083-0
A1'A41CO147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/13/02
• Date Rec'd (lab): 02/14/02
Project #: MBO-025AB Analysis Date: 02/14/02
Analyst: D. Agarest
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
•
Sample #: Sample Location: Sam ple Work 02PCM # Volume Duration Concentration
Type Location (min.} floc
03Pers - Leonard Lewis - Personal Entire
2711 75 30 0.6742
P11 ST EL Building
Leonard Lewis Personal Entire
04Pers 2712 350 140 0.1028
PII TWA Building
l..eanard1awL,._._.-. Personal Entire
14Pers 2722 288 120 0.0566
PII TWA Building
18Pers - Leonard Lerris Personal Entire
2726 414 ( 180 0.0473
PII TWA Building
20 Blank Blank N/A 2728 0 0 N/A
•
21 Blank Blank N/A 2729 0 0 N/A
Total Duration Sampled (min.) 470
Short Term Exposure Limit (STEL) 0.674:
8 hr. Time Weighted Average (TWA) 0.1040
fl
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is expcsed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (20) minutes. as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (20) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
* Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. '• Sample information is provided by the client & presented as stated. ** Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCart - Laboratory Director
NYC-WTC 000103555