NYC 9/11 Public Portal Document
TESTWELJ ,LABORATORIES, INC.
Environmental ~.Aboratory NYS ELAP # 11142
9Db 47 Hudson Street, Ossining, New York 10562 NVLAP # 200083-0
AIHA # 1C0147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/13102
Date Rec'd (lab): 02/14/02
Project #: MBO-025AB Analysis Date: 02/14/02
Analyst: D. Agarest
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
•
Field Technician: K. Laverenko/S. Manukov
Sample Work Duration Concentration
Sample #: Sample Location: 02PCM # Volume
Type Location (min.) f/cc
~SachowskitiDavid Personal Entire
01Pers 2709 75 30 0.7809
Building
Sachowski, David Personal Entire
02Pers 2710 375 150 0.0052
Pii TWA Building
Sachowski,_Dav_id_, Personal Entire
13Pers 2721 288 120 0.0060
PII TWA Building
Sachowski. David-.-., Personal Entire
19Pers PII 2727 414 180 0.0964
TINA Building
20 Blank Blank N/A 2728 0 0 N/A
21 Blank Blank N/A 2729 0 0 N/A
Total Duration Sampled (min.) 480
Short Term Exposure Limit (STEL) 0.7805
8 hr. Time Weighted Average (TWA) 0.0881
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
S
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of cur
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
A
Deborah McCart - Laboratory Director
NYC-WTC 000103552
OCR can misread numbers and units. Confirm readings against the page image before using them.