NYC 9/11 Public Portal Document
JJL TESTWELL LABORATORIES, INC.
1 Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NrS SLAP 511142
NVLAas2000S3-0
AIHA # 100147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/20/02
Date Rec'd (lab): 02/21/02
Project#: MBO-025AB Analysis Date: 02/21/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
0 55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location: I Sample Work
02PCM # Volume
Duration Concentration
Type Location
I (min.) f/cc
02Pers
Joe._Salemo._._._._ Personal Scaffold
3241 525 210 0.0051
PII TWA Entire
Joe Sal_e_m_ _o_ Personal Scaffold
07Pers ------ - Pii- 3246 360 150 0.0075
- - TWA Entire
10 Blank Blank N/A 3249 0 0 N/A
11 Blank Blank N/A 3250 0 0 N/A
Total Duration Sampled (min.) 360
8 hr. Time Weighted Average (TWA) 0.0046
(c) Permissible exposure Omits (PELS)
a
(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
ltimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
I
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
with HEPA
Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
• calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. •"' The laboratory has no control over air sampling collection, Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCall - Laboratory Director
NYC-WTC 000103474