NYC 9/11 Public Portal Document
TESTWEL LABORATORIES, INC.
• L Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYSElAP#11142
M/LAP#200083.0
AHA # 1C0147
PCM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/14/02
Date Rec'd (lab): 02/15/02
Project #: MBO-025AB Analysis Date: 02/15/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
• New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample Work
Sample
P #: Sample
P Location:
Type Location
OZPCM # Volume
_
tD uration Concentration
(min.) f/cc
02Pers _ _._._.LeonardLewis._._., Personal Entire
Ph i 2808 75 30 0.0687
STEL Building
04Pers __. Leonard L_e_w_is_- - Personal Entire
TWA 2810 525 210 0.0051
PII Building
S 07Pers
_._Leonard Lewis_._. Personal Entire
2813 576
Building 240 0.0222
10 Blank Blank N/A 2816 0 0 N/A
11 Blank Blank N/A 2817 0 0 N/A
Total Duration Sampled (min.) 480
Short Term Exposure Limit (STEL) 0.068'
8 hr. Time Weighted Average (TWA) 0.0171
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
i2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
ltimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
an equivalent method.
air respirator equip with HEPA
` Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "'• The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
•
Deborah McCarr - Laboratory Director
NYC-WTC 000103545