NYC 9/11 Public Portal Document
TESTWEL _ABORATORIES, INC.
• L Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYS FLAP x
NVIAPa200083.0
11142
AIH1z 100147
rPCM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/14/02
Date Rec'd (lab): 02/15/02
Project #: MBO-025AB Analysis Date: 02/15/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
• New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Work Duration Concentration
Sample Location: 02PCM # Volume
Type Location — (min.) f/cc
Sachowski, David Personal Entire
01Pers 2807 75 30 0.0360
Pii STEL Building
Sachowski, David Personal Entire
03Pers 2809 525 210 0.0051
PII TWA Building
08Pers _. _Sachowski, David Personal Entire
2714 528 220 0.0334
TWA Building
10 Blank Blank N/A 2816 0 0 N/A
11 Blank Blank N/A 2817 0 0 N/A
Total Duration Sampled (min.) 460
Short Term Exposure Limit (STEL) 0.0360
8 hr. Time Weighted Average (TWA) 0.0199
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section. or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
' Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
• calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is providedby the client & presented as stated. •" Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
•
Deborah McCall - Laboratory Director
NYC-WTC 000103543