NYC 9/11 Public Portal Document
•
L TESTWEL' '.ABORATORIES, INC.
Environmental Laboratory NYS ELAP # 11142
47 Hudson Street, Ossining, New York 10562 tPAAP0200083-0
ALMA #100147
PPCM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/14/02
Date Recd (lab): 02/15/02
Project #: MSO-025AB Analysis Date: 02/15/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
. New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample Work Duration Concentration
Sample #: Sample Location: 02PCM # Volume
Type Location (min.) f/cc
04Pers , .htlit:kiaal.Carlsnm_. Personal Glass
P11 STEL Delivery 2798 75 30 0.0392
08Pers , .Mtohael_.0 rlson._._.,
P11
Personal
TWA
Glass
Delivery
2802 445 178 1 0.0154
S 10Pers
_.Michael Cafl*q.tl-...-
__________________________
PII
1 Personal
7NA
Glass
Delivery
2804 432 180 I 0.0782
11 Blank Elank N/A 2805 0 0 N/A
12 Blank =lank N/A 2806 0 0 N/A
Total Duration Sampled (min.) 388
Short Term Exposure Limit (STEL) 0.0392
8 hr. Time Weighted Average (TWA) 0.0375
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is ex--.csed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (3C) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is excsed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
RespIratory Protection: Half face negative air respirator equip with HE?A cartridge.
Respiratory
Limit of quantitation based on volume of air collected and 5.51/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. "' Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
S
Deborah McC
cCarf --Laboratory Director
S
NYC-WTC 000103540