NYC 9/11 Public Portal Document
TESTWELL LABORATORIES, INC.
1 LL Environmental Laboratory
47 Hudson Street, Ossining, New York 10562
NYS ELAP 4 11142
NVLAP #200083-c
AIHA d 100147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/14/02
Date Rec'd (lab): 02/15/02
Project #: MBO-025AB Analysis Date: 02/15/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample _Work Duration Concentration
Sample #: Sample Location: 82PCM #J Volume
Type Location (min.) f/cc
R. Byine Personal Scaffold
02Pers 2796 75 30 0.0360
PII STEL Entire
R. Byine Personal Scaffold
05Pers ---- -- - ~ 2800 660 300 0.0108
P11 TWA Entire
11 Blank Blank N/A 2805 0 0 N/A
12 Blank Blank N/A 2806 0 0 N/A
Total Duration Sampled (min.) 330
Short Term Exposure Limit (STEL) 0.036(
8 hr. Time Weighted Average (TWA) 0.009(
(c) Permissible exposure limits (PELS)
S
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
• by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
Limit of quantitation based on volume of air collected and 5.5 f/1 00 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product-endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCarf - Laboratory Director
_ -
NYC-WTC 000103536