NYC 9/11 Public Portal Document
TESTWEL -'_ABORATORIES, INC.
• Environmental Laboratory NYS EtAP # 11142
47 Hudson Street, Ossining, New York 10562 !NEAP#200083-0
AJMA # 100147
PCM. AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/15/02
• Date Rec'd (lab): 02/16/02
Project #: MBO-025AB Analysis Date: 02/16/02
• Analyst: L. Chivarini
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
• New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location: Sample Work Duration Concentration
02PCM # Volume
Type Location (min.) f/cc
I
Michael Carlson Personal 14th -22nd
04Pers 2889 75 30 0.0360
--.Mit h i-Carlson.-.-.-.. Personal 14th - 22nd
05Pers 2890 200 120 0.0135
P11 TWA Floors
Michael Carlson Personal 14th - 22nd
09Pers 2894 432 180 0.0062
P11 1 TWA Floors
11 Blank Blank N/A 2896 0 0 N/A
12 Blank Blank N/A 2897 0 0 N/A
S
Total Duration Sampled (min.) 330
Short Term Exposure Limit (STEL) 0.0360
8 hr. Time Weighted Average (TWA) 0.0080
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes. as determined by the method prescribed in Appendix A to this section. or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
I • Limit of quantitation based on volume of air collected and 5.51/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "• Laboratory QC
data available upon request. "** The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
727
Deborah McCart - Laboratory Director
NYC-WTC 000103522