NYC 9/11 Public Portal Document
TESTWEL. _ABORATORIES, INC.
• Environmental Laboratory NYSELAP911142
47 Hudson Street, Ossining, New York 10562 W1t 0200083-0
ANA # 100147
PCM AIR SAMPLE RESULTS
• Client: Bovis Lend Lease Date Collected: 02/19/02
• Date Rec'd (lab): 02/20/02
Project #: MBO-025AB Analysis Date: 02/20/02
Analyst: D. Agrest
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
•
Field Technician: K. Laverenko/S. Manukov
Sample Work Duration Concentration
Sample #: Sample Location: 02PCM # Volume
Type Location _ (min.) f/cc
. ctor_Scto._._._._., Personal 18th - 22nd
05Pers 3125 75 30 0.0654
pll STEL Floors
_._.Victor Soto _ Personal 18th - 22nd
07Pers 3127 300 120 0.0149
L PII TWA Floors
- tor Soto._._._._., Personal 18th - 22nd
11Pers 3131 375 150 0.0159
PII TWA Floors
15 Blank Blank N/A 3135 0 0 N/A
16 Blank Blank N/A 3136 0 0 N!A
Total Duration Sampled (min.) 300
Short Term Exposure Limit (STEL) 0.0654
8 hr. Time Weighted Average (TWA) 0.012E
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes. as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
Limit of quantitation based on volume of air collected and 5.5 f1100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. " Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCall - Laboratory Director
NYC-WTC 000103512
OCR can misread numbers and units. Confirm readings against the page image before using them.