NYC 9/11 Public Portal Document
TESTWELI--LABORATORIES, INC.
Environmental Laboratory M$ELAP#11142
47 Hudson Street, Ossining, New York 10562 NVLAP 8200083-0
AIHA # 100147
PCM AIR SAMPLE RESULTS
Client: Bovis Lend Lease Date Collected: 02/20/02
Date Rec'd (lab): 02/21/02
Project #: MBO-025AB Analysis Date: 02/21/02
Analyst: J. Yarusso
Sample Location: The Millenium Hilton
55 Chruch Street Analytical Method: NIOSH 7400
New York, New York
Field Technician: K. Laverenko/S. Manukov
Sample #: Sample Location:
Sample
Type
I Location
Work
02PCM # Volume
1
Duration Concentration
(min.) f/cc
Sal Maddox Personal Entire
09Pers ------ --------P11 3228 75 30 0.0360
STEL Building
Sal_ Maddox_._._._._._. Personal Entire
10Pers 3229 300 120 0.0090
PII TWA Building
Sal Maddox Personal Entire
15Pers ----------- --- ------------ - 3234 312 130 0.0086
PII TWA Building
Sal Maddox Personal Entire
18Pers ------ - ---- ----------- - 3237 352 160 0.0885
Pil TWA Building
19 Blank Blank NIA 3238 0 0 N/A
20 Blank Blank N/A 3239 0 0 N/A
Total Duration Sampled (min.) 440
Short Term Exposure Limit (STEL) 0.036(
8 hr. Time Weighted Average (TWA) 0.036:
(c) Permissible exposure limits (PELS)
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section, or
by an equivalent method.
(c)(2) Excursion limit. The employer shall ensure that no employee is exposed to an airborne concentration of asbestos in excess of 1.0 fiber per cubic
centimeter of air (1 f/cc) as averaged over a sampling period of thirty (30) minutes, as determined by the method prescribed in Appendix A to this section. or
by an equivalent method.
Respiratory Protection: Half face negative air respirator equip with HEPA cartridge.
* Limit of quantitation based on volume of air collected and 5.5 f/100 fields as per the NIOSH 7400 method. The report value is
calculated by using the higher value of either the actual concentration or the-limit of quantification reported at P(0.05) indicating the 95%
confidence level at 2 standard deviations. ** Sample information is provided by the client & presented as stated. "' Laboratory QC
data available upon request. "" The laboratory has no control over air sampling collection. Reports are the confidential property of our
clients. This certificate of analysis/report shall not be used by the client to claim product endorsement by the National Voluntary
Laboratory Approval Program (NVLAP) or any agency of the United States Government. This certificate of analysis/report shall not be
reproduced except in full, without the written approval of Testwell Laboratories, Inc.
Deborah McCarl - Laboratory Director